Skip to main content
Journal cover image

Properties of acoustical speckle in the presence of phase aberration. Part II: Correlation lengths.

Publication ,  Journal Article
Smith, SW; Trahey, GE; Hubbard, SM; Wagner, RF
Published in: Ultrasonic imaging
January 1988

In recent years, analysis of the second order statistics of ultrasound speckle has led to accurate prediction and measurements of the average speckle size in the transducer focal zone. In this paper, that work has been extended to the average speckle size as determined by the normalized autocovariance in the presence of transducer phase aberrations. In general, a phase aberration causes a narrowing of the main lobe of the normalized autocovariance in the lateral direction. However, the lateral speckle autocovariance also showed significant side lobes in the presence of phase aberrations, indicating that individual speckles in a region of interest are not independent but are correlated so that less information is present for the task of signal detection when a transducer phase aberration exists. The same evidence of correlated speckle was found in the near field of a transducer in the region of fine speckle texture. This explanation satisfies the quandary of poor detectability in the near field region where the speckle is fine but the lateral resolution is quite degraded. The axial speckle in the presence of phase aberrations showed a small increase in main lobe widths and no evidence of side lobes. Beginning in 1978, the analysis of the second order statistics of speckle images for the purpose of spatial compounding led to accurate measurement and prediction of the cross-correlation curve as a function of transducer aperture translation for purposes of spatial compounding. In this paper, that work has been extended to the presence of transducer phase aberrations. The existence of transducer phase aberrations causes significant increases in the rate of decorrelation of speckle interference patterns as a transducer is translated. This indicates that spatial compounding will result in quite significant improvements in area-wise SNR and low contrast lesion detection for the case of severe random aberrators or focal point errors.

Duke Scholars

Published In

Ultrasonic imaging

DOI

EISSN

1096-0910

ISSN

0161-7346

Publication Date

January 1988

Volume

10

Issue

1

Start / End Page

29 / 51

Related Subject Headings

  • Ultrasonography
  • Quality Control
  • Humans
  • Acoustics
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Smith, S. W., Trahey, G. E., Hubbard, S. M., & Wagner, R. F. (1988). Properties of acoustical speckle in the presence of phase aberration. Part II: Correlation lengths. Ultrasonic Imaging, 10(1), 29–51. https://doi.org/10.1177/016173468801000103
Smith, S. W., G. E. Trahey, S. M. Hubbard, and R. F. Wagner. “Properties of acoustical speckle in the presence of phase aberration. Part II: Correlation lengths.Ultrasonic Imaging 10, no. 1 (January 1988): 29–51. https://doi.org/10.1177/016173468801000103.
Smith SW, Trahey GE, Hubbard SM, Wagner RF. Properties of acoustical speckle in the presence of phase aberration. Part II: Correlation lengths. Ultrasonic imaging. 1988 Jan;10(1):29–51.
Smith, S. W., et al. “Properties of acoustical speckle in the presence of phase aberration. Part II: Correlation lengths.Ultrasonic Imaging, vol. 10, no. 1, Jan. 1988, pp. 29–51. Epmc, doi:10.1177/016173468801000103.
Smith SW, Trahey GE, Hubbard SM, Wagner RF. Properties of acoustical speckle in the presence of phase aberration. Part II: Correlation lengths. Ultrasonic imaging. 1988 Jan;10(1):29–51.
Journal cover image

Published In

Ultrasonic imaging

DOI

EISSN

1096-0910

ISSN

0161-7346

Publication Date

January 1988

Volume

10

Issue

1

Start / End Page

29 / 51

Related Subject Headings

  • Ultrasonography
  • Quality Control
  • Humans
  • Acoustics
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering