Skip to main content

A novel implantable cardiac telemetry system for studying atrial fibrillation

Publication ,  Journal Article
Au-Yeung, K; Johnson, CR; Wolf, PD
Published in: Physiol. Meas. (UK)
2004

Atrial fibrillation (AF) is the most common arrhythmia in clinical practice. Most in vivo experimental research on AF is performed in a surgical setting, on animals instrumented by external devices, or using commercial implantable pacemakers. This paper describes a novel implantable cardiac telemetry system, which allows the study of AF remotely in conscious and ambulatory animals over a few month period. To validate this concept, the system was built and implanted in a sheep for 3 months. During this period, the system was used to deliver chronic rapid atrial pacing for AF induction, and to record and measure atrial electrograms and atrial effective refractory period (AERP) daily. During the course of AF induction the AERP decreased, confirming the progression of the electrical remodeling process in the atria. Episodes of paroxysmal AF were successfully induced in the animal. Burst pacing therapy was delivered with the system, however, no AF termination was observed. Result shows that this telemetry-based pacing and monitoring system can be used to study AF in a conscious animal non-invasively for an extended period of time, making this system a unique research tool

Duke Scholars

Published In

Physiol. Meas. (UK)

DOI

Publication Date

2004

Volume

25

Issue

5

Start / End Page

1223 / 1238

Related Subject Headings

  • Telemetry
  • Sheep
  • Prostheses and Implants
  • Heart Rate
  • Electrocardiography
  • Biomedical Engineering
  • Atrial Fibrillation
  • Animals
  • 4003 Biomedical engineering
  • 3208 Medical physiology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Au-Yeung, K., Johnson, C. R., & Wolf, P. D. (2004). A novel implantable cardiac telemetry system for studying atrial fibrillation. Physiol. Meas. (UK), 25(5), 1223–1238. https://doi.org/10.1088/0967-3334/25/5/012
Au-Yeung, Kityee, C. R. Johnson, and P. D. Wolf. “A novel implantable cardiac telemetry system for studying atrial fibrillation.” Physiol. Meas. (UK) 25, no. 5 (2004): 1223–38. https://doi.org/10.1088/0967-3334/25/5/012.
Au-Yeung K, Johnson CR, Wolf PD. A novel implantable cardiac telemetry system for studying atrial fibrillation. Physiol Meas (UK). 2004;25(5):1223–38.
Au-Yeung, Kityee, et al. “A novel implantable cardiac telemetry system for studying atrial fibrillation.” Physiol. Meas. (UK), vol. 25, no. 5, 2004, pp. 1223–38. Manual, doi:10.1088/0967-3334/25/5/012.
Au-Yeung K, Johnson CR, Wolf PD. A novel implantable cardiac telemetry system for studying atrial fibrillation. Physiol Meas (UK). 2004;25(5):1223–1238.

Published In

Physiol. Meas. (UK)

DOI

Publication Date

2004

Volume

25

Issue

5

Start / End Page

1223 / 1238

Related Subject Headings

  • Telemetry
  • Sheep
  • Prostheses and Implants
  • Heart Rate
  • Electrocardiography
  • Biomedical Engineering
  • Atrial Fibrillation
  • Animals
  • 4003 Biomedical engineering
  • 3208 Medical physiology