A major problem in the gradient-recalled echo-planar imaging (EPI) method that also uses a long echo time (TE) is the severe signal loss in regions with large static field inhomogeneities. These regions include the ventral frontal, medial temporal, and inferior temporal lobes, which experience inhomogeneities induced by susceptibility effects commonly found near air/tissue interfaces. For functional magnetic resonance imaging (fMRI) studies that use both gradient-recalled EPI at relatively long TE and high-field scanners, this signal loss is severe, preventing investigation of certain human cognitive processes that involve these regions, such as memory and attention. Methods have been developed to recover this signal loss; however, most of them require multiple excitations and thus compromise temporal resolution. In this report, a new technique is described which achieves good signal recovery within a single excitation. It is anticipated that this technique will prove useful for fMRI studies in inhomogeneous areas that require high temporal resolution.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

August 2001

Volume

46

Issue

2

Start / End Page

407 / 411

Location

United States

Related Subject Headings

  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Echo-Planar Imaging
  • Brain Mapping
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Song, A. W. (2001). Single-shot EPI with signal recovery from the susceptibility-induced losses. Magn Reson Med, 46(2), 407–411. https://doi.org/10.1002/mrm.1205
Song, A. W. “Single-shot EPI with signal recovery from the susceptibility-induced losses.Magn Reson Med 46, no. 2 (August 2001): 407–11. https://doi.org/10.1002/mrm.1205.
Song, A. W. “Single-shot EPI with signal recovery from the susceptibility-induced losses.Magn Reson Med, vol. 46, no. 2, Aug. 2001, pp. 407–11. Pubmed, doi:10.1002/mrm.1205.
Song AW. Single-shot EPI with signal recovery from the susceptibility-induced losses. Magn Reson Med. 2001 Aug;46(2):407–411.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

August 2001

Volume

46

Issue

2

Start / End Page

407 / 411

Location

United States

Related Subject Headings

  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Echo-Planar Imaging
  • Brain Mapping
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering