Skip to main content
Journal cover image

Single-voxel 1H PRESS at 4.0 T: precision and variability of measurements in anterior cingulate and hippocampus.

Publication ,  Journal Article
Venkatraman, TN; Hamer, RM; Perkins, DO; Song, AW; Lieberman, JA; Steen, RG
Published in: NMR Biomed
June 2006

The precision [coefficient of variation or CV (%) = 100SD/X] of single-voxel point resolved spectroscopic data was characterized bilaterally, in anterior cingulate and in hippocampus, at 4.0 T in a healthy subject. Data acquisition was replicated 10 times after voxel repositioning and readjusting higher order shims. Precision measurements show that the scan-to-scan precision is better in anterior cingulate than in hippocampus, with an average CV of 9.2% (for total NAA, tCho and Cr) in anterior cingulate and 13.9% in hippocampus. Variability measurements made by the same method in 24 healthy subjects and in 29 schizophrenia patients showed that there is substantial biological variability in metabolite levels, even in healthy subjects. Simple calculations suggest that more than 200 subjects would be needed to detect a 5% difference in NAA between patients and controls.

Duke Scholars

Published In

NMR Biomed

DOI

ISSN

0952-3480

Publication Date

June 2006

Volume

19

Issue

4

Start / End Page

484 / 491

Location

England

Related Subject Headings

  • Tissue Distribution
  • Sensitivity and Specificity
  • Schizophrenia
  • Sample Size
  • Reproducibility of Results
  • Protons
  • Nuclear Medicine & Medical Imaging
  • Neurotransmitter Agents
  • Male
  • Magnetic Resonance Spectroscopy
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Venkatraman, T. N., Hamer, R. M., Perkins, D. O., Song, A. W., Lieberman, J. A., & Steen, R. G. (2006). Single-voxel 1H PRESS at 4.0 T: precision and variability of measurements in anterior cingulate and hippocampus. NMR Biomed, 19(4), 484–491. https://doi.org/10.1002/nbm.1055
Venkatraman, Talaignair N., Robert M. Hamer, Diana O. Perkins, Allen W. Song, Jeffrey A. Lieberman, and R Grant Steen. “Single-voxel 1H PRESS at 4.0 T: precision and variability of measurements in anterior cingulate and hippocampus.NMR Biomed 19, no. 4 (June 2006): 484–91. https://doi.org/10.1002/nbm.1055.
Venkatraman TN, Hamer RM, Perkins DO, Song AW, Lieberman JA, Steen RG. Single-voxel 1H PRESS at 4.0 T: precision and variability of measurements in anterior cingulate and hippocampus. NMR Biomed. 2006 Jun;19(4):484–91.
Venkatraman, Talaignair N., et al. “Single-voxel 1H PRESS at 4.0 T: precision and variability of measurements in anterior cingulate and hippocampus.NMR Biomed, vol. 19, no. 4, June 2006, pp. 484–91. Pubmed, doi:10.1002/nbm.1055.
Venkatraman TN, Hamer RM, Perkins DO, Song AW, Lieberman JA, Steen RG. Single-voxel 1H PRESS at 4.0 T: precision and variability of measurements in anterior cingulate and hippocampus. NMR Biomed. 2006 Jun;19(4):484–491.
Journal cover image

Published In

NMR Biomed

DOI

ISSN

0952-3480

Publication Date

June 2006

Volume

19

Issue

4

Start / End Page

484 / 491

Location

England

Related Subject Headings

  • Tissue Distribution
  • Sensitivity and Specificity
  • Schizophrenia
  • Sample Size
  • Reproducibility of Results
  • Protons
  • Nuclear Medicine & Medical Imaging
  • Neurotransmitter Agents
  • Male
  • Magnetic Resonance Spectroscopy