Skip to main content

Correlation of SPECT images of a three-dimensional brain phantom using a surface fitting technique

Publication ,  Journal Article
Turkington, TG; Jaszczak, RJ; Greer, KL; Coleman, RE; Pelizzari, CA
Published in: IEEE Transactions on Nuclear Science
January 1, 1992

The accuracy of a surface fitting technique was investigated for registration of SPECT brain images. Fiduciary markers were placed on the outside of a three-dimensional brain phantom filled with Tc-99m solution. The phantom and markers were scanned at several orientations in the scanner and contours were produced for the slices of each set. Parameters were fit to rotate and translate images acquired at each orientation to match the images acquired at each of the other orientations. Independent fits based on the measured marker positions were done to determine the rotational and translational parameters more precisely. The maximum error measured in the translational parameters was less than 1/2 pixel (1.8 mm) in any direction and the errors in the angle parameters were all less than 3 degrees, with most less than 1.5 degrees. © 1992 IEEE

Duke Scholars

Published In

IEEE Transactions on Nuclear Science

DOI

EISSN

1558-1578

ISSN

0018-9499

Publication Date

January 1, 1992

Volume

39

Issue

5

Start / End Page

1460 / 1463

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Turkington, T. G., Jaszczak, R. J., Greer, K. L., Coleman, R. E., & Pelizzari, C. A. (1992). Correlation of SPECT images of a three-dimensional brain phantom using a surface fitting technique. IEEE Transactions on Nuclear Science, 39(5), 1460–1463. https://doi.org/10.1109/23.173224
Turkington, T. G., R. J. Jaszczak, K. L. Greer, R. E. Coleman, and C. A. Pelizzari. “Correlation of SPECT images of a three-dimensional brain phantom using a surface fitting technique.” IEEE Transactions on Nuclear Science 39, no. 5 (January 1, 1992): 1460–63. https://doi.org/10.1109/23.173224.
Turkington TG, Jaszczak RJ, Greer KL, Coleman RE, Pelizzari CA. Correlation of SPECT images of a three-dimensional brain phantom using a surface fitting technique. IEEE Transactions on Nuclear Science. 1992 Jan 1;39(5):1460–3.
Turkington, T. G., et al. “Correlation of SPECT images of a three-dimensional brain phantom using a surface fitting technique.” IEEE Transactions on Nuclear Science, vol. 39, no. 5, Jan. 1992, pp. 1460–63. Scopus, doi:10.1109/23.173224.
Turkington TG, Jaszczak RJ, Greer KL, Coleman RE, Pelizzari CA. Correlation of SPECT images of a three-dimensional brain phantom using a surface fitting technique. IEEE Transactions on Nuclear Science. 1992 Jan 1;39(5):1460–1463.

Published In

IEEE Transactions on Nuclear Science

DOI

EISSN

1558-1578

ISSN

0018-9499

Publication Date

January 1, 1992

Volume

39

Issue

5

Start / End Page

1460 / 1463

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics