Publication ,  Journal Article
O'Malley Schotthoefer, E; Yanovitch, TL; Freedman, SF
Published in: J AAPOS
February 2008

PURPOSE: To determine the prevalence of complications relating to ocular motility and alignment in children with refractory congenital and aphakic glaucoma treated with aqueous drainage device surgery. METHODS: Chart review of consecutive children treated with aqueous drainage devices at Duke University Eye Center from 1995 to 2006 for ocular motility abnormalities and strabismus as well as sensorimotor testing results before and after aqueous drainage device placement. RESULTS: Thirty-eight eyes of 30 children with congenital glaucoma and 41 eyes of 32 children with aphakic glaucoma were included. Optotype visual acuity testing could be performed in a minority of children preoperatively. After aqueous drainage device surgery, 14 and 20 eyes, respectively, were >20/100 in the congenital glaucoma and aphakic glaucoma groups. Only a few children had stereopsis or demonstrated binocular function on Worth 4-Dot testing in both groups before and after aqueous drainage device surgery. Horizontal and vertical strabismus was common, especially after aqueous drainage device surgery and occurred in 57% of congenital glaucoma patients and 47% of aphakic glaucoma patients. Motility limitation (both vertical and horizontal) was also common and occurred in 37% overall. DISCUSSION: Ocular motility abnormalities and strabismus were common in children after aqueous drainage device surgery. These potential problems should be considered when aqueous drainage device surgery is planned, especially in children with binocularity.

Duke Scholars

Published In

J AAPOS

DOI

EISSN

1528-3933

Publication Date

February 2008

Volume

12

Issue

1

Start / End Page

40 / 45

Location

United States

Related Subject Headings

  • Visual Acuity
  • Treatment Outcome
  • Strabismus
  • Retrospective Studies
  • Prosthesis Design
  • Postoperative Complications
  • Ophthalmology & Optometry
  • Intraocular Pressure
  • Infant
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
O’Malley Schotthoefer, E., Yanovitch, T. L., & Freedman, S. F. (2008). Aqueous drainage device surgery in refractory pediatric glaucoma: II. Ocular motility consequences. J AAPOS, 12(1), 40–45. https://doi.org/10.1016/j.jaapos.2007.07.005
O’Malley Schotthoefer, Erin, Tammy L. Yanovitch, and Sharon F. Freedman. “Aqueous drainage device surgery in refractory pediatric glaucoma: II. Ocular motility consequences.J AAPOS 12, no. 1 (February 2008): 40–45. https://doi.org/10.1016/j.jaapos.2007.07.005.
O’Malley Schotthoefer E, Yanovitch TL, Freedman SF. Aqueous drainage device surgery in refractory pediatric glaucoma: II. Ocular motility consequences. J AAPOS. 2008 Feb;12(1):40–5.
O’Malley Schotthoefer, Erin, et al. “Aqueous drainage device surgery in refractory pediatric glaucoma: II. Ocular motility consequences.J AAPOS, vol. 12, no. 1, Feb. 2008, pp. 40–45. Pubmed, doi:10.1016/j.jaapos.2007.07.005.
O’Malley Schotthoefer E, Yanovitch TL, Freedman SF. Aqueous drainage device surgery in refractory pediatric glaucoma: II. Ocular motility consequences. J AAPOS. 2008 Feb;12(1):40–45.
Journal cover image

Published In

J AAPOS

DOI

EISSN

1528-3933

Publication Date

February 2008

Volume

12

Issue

1

Start / End Page

40 / 45

Location

United States

Related Subject Headings

  • Visual Acuity
  • Treatment Outcome
  • Strabismus
  • Retrospective Studies
  • Prosthesis Design
  • Postoperative Complications
  • Ophthalmology & Optometry
  • Intraocular Pressure
  • Infant
  • Humans