Analysis of the early rise in aortic transvalvular gradient after aortic valvuloplasty.

Publication ,  Journal Article
Davidson, CJ; Harpole, DA; Kisslo, K; Skelton, TN; Kisslo, J; Jones, RH; Bashore, TM
Published in: Am Heart J
February 1989

The relationship between dynamic changes in aortic valve gradient and left ventricular ejection performance in the early period after successful percutaneous aortic valvuloplasty has not been described in detail. Accordingly 20 adult patients with severe symptomatic calcific aortic stenosis underwent first-pass radionuclide angiography and Doppler echocardiography before, immediately after, and 2 to 4 days after the valvuloplasty procedure. A significant (p less than 0.001) reduction in peak-to-peak (72 +/- 24 mm Hg to 36 +/- 11 mmHg) and mean (60 +/- 20 mm Hg to 34 +/- 9 mm Hg) transaortic gradient and an increase in aortic valve area (0.5 +/- 0.2 cm2 to 0.8 +/- 0.2 cm2) were measured by high-fidelity micromanometer catheters immediately after aortic valvuloplasty. Results of Doppler echocardiography showed a significant (p less than 0.001) immediate decrease in peak instantaneous (81 +/- 22 mm Hg to 53 +/- 15 mm Hg) and mean (48 +/- 14 mm Hg to 31 +/- 9 mm Hg) aortic gradients. However, 2 to 4 days later a significant (p less than 0.001) return of peak (56 +/- 15 mm Hg to 65 +/- 20 mm Hg) and mean (31 +/- 9 mm Hg to 39 +/- 12 mm Hg) transvalvular gradient occurred. Aortic valve area as determined by the continuity equation also increased from 0.4 +/- 0.2 cm2 to 0.6 +/- 0.2 cm2 immediately after the procedure (p less than 0.001), then partially returned to baseline (0.5 +/- 0.2 cm2; p less than 0.005) at 2 to 4 days.(ABSTRACT TRUNCATED AT 250 WORDS)

Duke Scholars

Published In

Am Heart J

DOI

ISSN

0002-8703

Publication Date

February 1989

Volume

117

Issue

2

Start / End Page

411 / 417

Location

United States

Related Subject Headings

  • Radionuclide Imaging
  • Middle Aged
  • Male
  • Humans
  • Hemodynamics
  • Heart Ventricles
  • Heart
  • Female
  • Echocardiography, Doppler
  • Catheterization
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Davidson, C. J., Harpole, D. A., Kisslo, K., Skelton, T. N., Kisslo, J., Jones, R. H., & Bashore, T. M. (1989). Analysis of the early rise in aortic transvalvular gradient after aortic valvuloplasty. Am Heart J, 117(2), 411–417. https://doi.org/10.1016/0002-8703(89)90788-6
Davidson, C. J., D. A. Harpole, K. Kisslo, T. N. Skelton, J. Kisslo, R. H. Jones, and T. M. Bashore. “Analysis of the early rise in aortic transvalvular gradient after aortic valvuloplasty.Am Heart J 117, no. 2 (February 1989): 411–17. https://doi.org/10.1016/0002-8703(89)90788-6.
Davidson CJ, Harpole DA, Kisslo K, Skelton TN, Kisslo J, Jones RH, et al. Analysis of the early rise in aortic transvalvular gradient after aortic valvuloplasty. Am Heart J. 1989 Feb;117(2):411–7.
Davidson, C. J., et al. “Analysis of the early rise in aortic transvalvular gradient after aortic valvuloplasty.Am Heart J, vol. 117, no. 2, Feb. 1989, pp. 411–17. Pubmed, doi:10.1016/0002-8703(89)90788-6.
Davidson CJ, Harpole DA, Kisslo K, Skelton TN, Kisslo J, Jones RH, Bashore TM. Analysis of the early rise in aortic transvalvular gradient after aortic valvuloplasty. Am Heart J. 1989 Feb;117(2):411–417.
Journal cover image

Published In

Am Heart J

DOI

ISSN

0002-8703

Publication Date

February 1989

Volume

117

Issue

2

Start / End Page

411 / 417

Location

United States

Related Subject Headings

  • Radionuclide Imaging
  • Middle Aged
  • Male
  • Humans
  • Hemodynamics
  • Heart Ventricles
  • Heart
  • Female
  • Echocardiography, Doppler
  • Catheterization