PURPOSE: To evaluate and compare human observer performance in a contrast-detail test by using postprocessed hard-copy images from a digital chest radiography system and conventional screen-film radiographs. MATERIALS AND METHODS: The digital radiography system is based on a large-area flat-panel x-ray detector with a structured cesium iodide scintillator layer and an amorphous silicon thin-film transistor array for image readout. Images of a contrast-detail phantom were acquired at two exposure levels by using two standard thoracic screen-film systems and the digital system at matched dose. By using images of the phantom processed with standard chest image postprocessing techniques, a four-alternative forced-choice observer perception study was performed, and the number of detectable test signals (disk-shaped objects 0.3-4.0 mm in diameter) was determined for each image type. RESULTS: On average, observers detected more test signals on digital images than on screen-film radiographs at all diameters up to 2.0 mm and an equivalent number at larger diameters. Test signals with lower inherent subject contrast were detected more readily on digital images than on screen-film images, even when x-ray exposure levels for the digital system were reduced by 20%. CONCLUSION: Observer performance in a contrast-detail detection task can be improved by using images acquired with the flat-panel digital chest radiography system as compared with those acquired with state-of-the-art screen-film combinations.

Duke Scholars

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

March 2001

Volume

218

Issue

3

Start / End Page

679 / 682

Location

United States

Related Subject Headings

  • Visual Perception
  • Radiography, Thoracic
  • Radiographic Image Enhancement
  • Phantoms, Imaging
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Humans
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chotas, H. G., & Ravin, C. E. (2001). Digital chest radiography with a solid-state flat-panel x-ray detector: contrast-detail evaluation with processed images printed on film hard copy. Radiology, 218(3), 679–682. https://doi.org/10.1148/radiology.218.3.r01mr27679
Chotas, H. G., and C. E. Ravin. “Digital chest radiography with a solid-state flat-panel x-ray detector: contrast-detail evaluation with processed images printed on film hard copy.Radiology 218, no. 3 (March 2001): 679–82. https://doi.org/10.1148/radiology.218.3.r01mr27679.
Chotas, H. G., and C. E. Ravin. “Digital chest radiography with a solid-state flat-panel x-ray detector: contrast-detail evaluation with processed images printed on film hard copy.Radiology, vol. 218, no. 3, Mar. 2001, pp. 679–82. Pubmed, doi:10.1148/radiology.218.3.r01mr27679.
Journal cover image

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

March 2001

Volume

218

Issue

3

Start / End Page

679 / 682

Location

United States

Related Subject Headings

  • Visual Perception
  • Radiography, Thoracic
  • Radiographic Image Enhancement
  • Phantoms, Imaging
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Humans
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences