Skip to main content
Journal cover image

Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography.

Publication ,  Journal Article
Floyd, CE; Warp, RJ; Dobbins, JT; Chotas, HG; Baydush, AH; Vargas-Voracek, R; Ravin, CE
Published in: Radiology
March 2001

PURPOSE: To evaluate the imaging characteristics of an amorphous silicon flat-panel detector (FPD) for digital chest radiography. MATERIALS AND METHODS: The 41 x 41-cm digital FPD is constructed on a single monolithic glass substrate with a structured cesium iodide scintillator layer and an amorphous silicon thin-film transistor array for image readout. Basic imaging characteristics of the FPD and associated image processing system were assessed on acquired images, including linearity, repeatability, uniformity of response, modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), contrast sensitivity, and scatter content. Results with the FPD system were compared to those with a storage phosphor computed radiography (CR) system. RESULTS: Images obtained with the FPD demonstrated excellent uniformity, repeatability, and linearity, as well as MTF and DQE that were superior to those with the storage phosphor CR system. The contrast and scatter content of images acquired with the FPD were equivalent to those acquired with the storage phosphor system. CONCLUSION: The FPD provides radiographic images with excellent inherent physical image quality.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

March 2001

Volume

218

Issue

3

Start / End Page

683 / 688

Location

United States

Related Subject Headings

  • Radiography, Thoracic
  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Evaluation Studies as Topic
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Floyd, C. E., Warp, R. J., Dobbins, J. T., Chotas, H. G., Baydush, A. H., Vargas-Voracek, R., & Ravin, C. E. (2001). Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography. Radiology, 218(3), 683–688. https://doi.org/10.1148/radiology.218.3.r01fe45683
Floyd, C. E., R. J. Warp, J. T. Dobbins, H. G. Chotas, A. H. Baydush, R. Vargas-Voracek, and C. E. Ravin. “Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography.Radiology 218, no. 3 (March 2001): 683–88. https://doi.org/10.1148/radiology.218.3.r01fe45683.
Floyd CE, Warp RJ, Dobbins JT, Chotas HG, Baydush AH, Vargas-Voracek R, et al. Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography. Radiology. 2001 Mar;218(3):683–8.
Floyd, C. E., et al. “Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography.Radiology, vol. 218, no. 3, Mar. 2001, pp. 683–88. Pubmed, doi:10.1148/radiology.218.3.r01fe45683.
Floyd CE, Warp RJ, Dobbins JT, Chotas HG, Baydush AH, Vargas-Voracek R, Ravin CE. Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography. Radiology. 2001 Mar;218(3):683–688.
Journal cover image

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

March 2001

Volume

218

Issue

3

Start / End Page

683 / 688

Location

United States

Related Subject Headings

  • Radiography, Thoracic
  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Evaluation Studies as Topic
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences