Skip to main content

A high-precision contrast injector for small animal x-ray digital subtraction angiography.

Publication ,  Journal Article
de Lin, M; Ning, L; Badea, CT; Mistry, NN; Qi, Y; Johnson, GA
Published in: IEEE Trans Biomed Eng
March 2008

The availability of genetically altered animal models of human disease for basic research has generated great interest in new imaging methodologies. Digital subtraction angiography (DSA) offers an appealing approach to functional imaging in small animals because of the high spatial and temporal resolution, and the ability to visualize and measure blood flow. The micro-injector described here meets crucial performance parameters to ensure optimal vessel enhancement without significantly increasing the total blood volume or producing overlap of enhanced structures. The micro-injector can inject small, reproducible volumes of contrast agent at high flow rates with computer-controlled timing synchronized to cardiopulmonary activity. Iterative bench-top and live animal experiments with both rat and mouse have been conducted to evaluate the performance of this computer-controlled micro-injector, a first demonstration of a new device designed explicitly for the unique requirements of DSA in small animals. Injection protocols were optimized and screened for potential physiological impact. For the optimized protocols, we found that changes in the time-density curves for representative regions of interest in the thorax were due primarily to physiological changes, independent of micro-injector parameters.

Duke Scholars

Published In

IEEE Trans Biomed Eng

DOI

ISSN

0018-9294

Publication Date

March 2008

Volume

55

Issue

3

Start / End Page

1082 / 1091

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiographic Image Enhancement
  • Microinjections
  • Mice
  • Iopamidol
  • Equipment Failure Analysis
  • Equipment Design
  • Contrast Media
  • Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
de Lin, M., Ning, L., Badea, C. T., Mistry, N. N., Qi, Y., & Johnson, G. A. (2008). A high-precision contrast injector for small animal x-ray digital subtraction angiography. IEEE Trans Biomed Eng, 55(3), 1082–1091. https://doi.org/10.1109/TBME.2007.909541
Lin, Ming de, Lutao Ning, Cristian T. Badea, Nilesh N. Mistry, Yi Qi, and G Allan Johnson. “A high-precision contrast injector for small animal x-ray digital subtraction angiography.IEEE Trans Biomed Eng 55, no. 3 (March 2008): 1082–91. https://doi.org/10.1109/TBME.2007.909541.
de Lin M, Ning L, Badea CT, Mistry NN, Qi Y, Johnson GA. A high-precision contrast injector for small animal x-ray digital subtraction angiography. IEEE Trans Biomed Eng. 2008 Mar;55(3):1082–91.
de Lin, Ming, et al. “A high-precision contrast injector for small animal x-ray digital subtraction angiography.IEEE Trans Biomed Eng, vol. 55, no. 3, Mar. 2008, pp. 1082–91. Pubmed, doi:10.1109/TBME.2007.909541.
de Lin M, Ning L, Badea CT, Mistry NN, Qi Y, Johnson GA. A high-precision contrast injector for small animal x-ray digital subtraction angiography. IEEE Trans Biomed Eng. 2008 Mar;55(3):1082–1091.

Published In

IEEE Trans Biomed Eng

DOI

ISSN

0018-9294

Publication Date

March 2008

Volume

55

Issue

3

Start / End Page

1082 / 1091

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiographic Image Enhancement
  • Microinjections
  • Mice
  • Iopamidol
  • Equipment Failure Analysis
  • Equipment Design
  • Contrast Media
  • Biomedical Engineering