Skip to main content

Multiplexed low coherence interferometry instrument for measuring microbicide gel thickness distribution.

Publication ,  Journal Article
Drake, TK; Robles, FE; Wax, A
Published in: Applied optics
April 2009

We present a Fourier-domain, multiplexed low coherence interferometry (LCI) instrument designed for application to intravaginal measurement of microbicidal gel distribution. Microbicide gels are topical products developed to combat sexually transmitted diseases, such as HIV/AIDS, by acting as delivery vehicles for active drugs and barrier layers to vaginal tissue. Measuring microbicide gel vaginal distribution is key to understanding the gel's biological effectiveness. This study presents a new LCI system for measuring gel distribution that uses six multiplexed channels to achieve broad area scanning without the need for a mechanical scanner. The presented results characterize the performance of the Fourier-domain multiplexed LCI system in measuring gel thickness distribution. The system demonstrates good optical signal-to-noise ratio, steady performance across all channels, negligible cross talk, and accurate measurement with micrometer scale resolution. The potential impact of using a multiplexed LCI system for in vivo measurements is also discussed.

Duke Scholars

Published In

Applied optics

DOI

EISSN

1539-4522

ISSN

1559-128X

Publication Date

April 2009

Volume

48

Issue

10

Start / End Page

D14 / D19

Related Subject Headings

  • Vagina
  • Tissue Distribution
  • Optics
  • Interferometry
  • Humans
  • Gels
  • Fourier Analysis
  • Female
  • Equipment Design
  • Anti-Infective Agents
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Drake, T. K., Robles, F. E., & Wax, A. (2009). Multiplexed low coherence interferometry instrument for measuring microbicide gel thickness distribution. Applied Optics, 48(10), D14–D19. https://doi.org/10.1364/ao.48.000d14
Drake, Tyler K., Francisco E. Robles, and Adam Wax. “Multiplexed low coherence interferometry instrument for measuring microbicide gel thickness distribution.Applied Optics 48, no. 10 (April 2009): D14–19. https://doi.org/10.1364/ao.48.000d14.
Drake, Tyler K., et al. “Multiplexed low coherence interferometry instrument for measuring microbicide gel thickness distribution.Applied Optics, vol. 48, no. 10, Apr. 2009, pp. D14–19. Epmc, doi:10.1364/ao.48.000d14.
Drake TK, Robles FE, Wax A. Multiplexed low coherence interferometry instrument for measuring microbicide gel thickness distribution. Applied optics. 2009 Apr;48(10):D14–D19.

Published In

Applied optics

DOI

EISSN

1539-4522

ISSN

1559-128X

Publication Date

April 2009

Volume

48

Issue

10

Start / End Page

D14 / D19

Related Subject Headings

  • Vagina
  • Tissue Distribution
  • Optics
  • Interferometry
  • Humans
  • Gels
  • Fourier Analysis
  • Female
  • Equipment Design
  • Anti-Infective Agents