Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and Definity in Mice.

Publication ,  Journal Article
Bing, KF; Howles, GP; Qi, Y; Palmeri, ML; Nightingale, KR
Published in: Ultrasound in medicine & biology
August 2009

The objective of this work was to determine whether diagnostic ultrasound and contrast agent could be used to transcranially and nondestructively disrupt the blood-brain barrier (BBB) in mice under ultrasound image guidance and to quantify that disruption using magnetic resonance imaging (MRI) and magnetic resonance (MR) contrast agent. Each mouse was placed under isoflurane anesthesia and the hair on top of its skull was removed before treatment. A diagnostic ultrasound transducer was placed in a water bag coupled with gel on the mouse skull. Definity (ultrasound [US] contrast) and Magnevist (MR contrast) were injected concurrent with the start of a custom ultrasound transmission sequence. The transducer was translated along the rostral-caudal axis to insonify three spatial locations (2mm apart) along one half of the brain for each sequence. T1-weighted MR images were used to quantify the volume of tissue over which the BBB disruption allowed Magnevist to enter the brain, based upon increases in MR contrast-to-noise ratio (CNR) compared with the noninsonified portions of the brain. Ultrasonic frequency, pressure and pulse duration, as well as Definity dose and injection time were varied. Preliminary results suggest that a threshold exists for BBB opening dependent upon both pressure and pulse duration (consistent with reports in the literature performed at lower frequencies). A range of typical diagnostic frequencies (e.g., 5.0-8.0 MHz) generated BBB disruption. Comparable BBB opening was noted with varied delays between Definity injection and insonification (0-2 min) for a range of Definity concentrations (400-2400 microL/kg). The low-pressure, custom sequences (mechanical index [MI]< or =0.65) had minimal blood cell extravasation as determined by histologic evaluation. This study has shown the ability of a diagnostic ultrasound system, in conjunction with Definity, to open the BBB transcranially in a mouse model for molecules approximately 0.5 kDa in size. Opening was achieved at higher frequencies than previously reported and was localized under ultrasound image guidance. A typical, ultrasound imaging mode (pulsed wave [PW] Doppler) with specific settings (transmit frequency=5.7 MHz, gate size=15 mm, pulse repetition frequency=100 Hz, system power=15%) successfully opened the BBB, which facilitates implementation using the most of commercially available clinical diagnostic scanners. Localized opening of the BBB may have potential clinical utility for the delivery of diagnostic or therapeutic agents to the brain.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ultrasound in medicine & biology

DOI

EISSN

1879-291X

ISSN

0301-5629

Publication Date

August 2009

Volume

35

Issue

8

Start / End Page

1298 / 1308

Related Subject Headings

  • Ultrasonography, Interventional
  • Mice, Inbred C57BL
  • Mice
  • Magnetic Resonance Imaging
  • Image Interpretation, Computer-Assisted
  • Gadolinium DTPA
  • Fluorocarbons
  • Echoencephalography
  • Contrast Media
  • Brain
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Bing, K. F., Howles, G. P., Qi, Y., Palmeri, M. L., & Nightingale, K. R. (2009). Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and Definity in Mice. Ultrasound in Medicine & Biology, 35(8), 1298–1308. https://doi.org/10.1016/j.ultrasmedbio.2009.03.012
Bing, Kristin Frinkley, Gabriel P. Howles, Yi Qi, Mark L. Palmeri, and Kathryn R. Nightingale. “Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and Definity in Mice.Ultrasound in Medicine & Biology 35, no. 8 (August 2009): 1298–1308. https://doi.org/10.1016/j.ultrasmedbio.2009.03.012.
Bing KF, Howles GP, Qi Y, Palmeri ML, Nightingale KR. Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and Definity in Mice. Ultrasound in medicine & biology. 2009 Aug;35(8):1298–308.
Bing, Kristin Frinkley, et al. “Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and Definity in Mice.Ultrasound in Medicine & Biology, vol. 35, no. 8, Aug. 2009, pp. 1298–308. Epmc, doi:10.1016/j.ultrasmedbio.2009.03.012.
Bing KF, Howles GP, Qi Y, Palmeri ML, Nightingale KR. Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and Definity in Mice. Ultrasound in medicine & biology. 2009 Aug;35(8):1298–1308.
Journal cover image

Published In

Ultrasound in medicine & biology

DOI

EISSN

1879-291X

ISSN

0301-5629

Publication Date

August 2009

Volume

35

Issue

8

Start / End Page

1298 / 1308

Related Subject Headings

  • Ultrasonography, Interventional
  • Mice, Inbred C57BL
  • Mice
  • Magnetic Resonance Imaging
  • Image Interpretation, Computer-Assisted
  • Gadolinium DTPA
  • Fluorocarbons
  • Echoencephalography
  • Contrast Media
  • Brain