Skip to main content

Sonographically guided thrombin injection of iatrogenic femoral pseudoaneurysms: further experience of a single institution.

Publication ,  Journal Article
Paulson, EK; Nelson, RC; Mayes, CE; Sheafor, DH; Sketch, MH; Kliewer, MA
Published in: AJR Am J Roentgenol
August 2001

OBJECTIVE: In September 1998, we began to treat iatrogenic femoral pseudoaneurysms with direct thrombin injection under sonographic guidance. Our purpose was to determine the success and complication rate of this technique. SUBJECTS AND METHODS: We treated 114 consecutive patients who had iatrogenic femoral pseudoaneurysms using direct thrombin injection. A 22-gauge spinal needle was placed into the pseudoaneurysm lumen with sonographic guidance, and bovine or human thrombin (mean dose, 306 U; range, 50--1600 U) was injected under continuous color Doppler sonographic visualization. Distal pulses were monitored. Patient demographics, clinical variables, and pseudoaneurysm characteristics were collected. RESULTS: One hundred three (90%) of 114 patients had pseudoaneurysm thrombosis after the first procedure. Of the remaining 11 patients who required a second procedure 1 day later, thrombosis occurred in seven (64%) of 11. Thus, the overall success rate was 96% (110/114). Of the patients who required one injection, the mean thrombosis time was 12 sec (range, 3--90 sec). Three (3%) of 114 patients required conscious sedation. Of the patients with successful thrombosis, 24-hr follow-up sonograms showed no recurrent pseudoaneurysm. Four patients (4%) had potential complications: a "blue toe" 15 hr after the thrombin injection that resolved spontaneously, a groin abscess, leg ischemia that resolved spontaneously after 4 hr, and crampy buttock pain that resolved spontaneously. CONCLUSION: For the treatment of iatrogenic femoral pseudoaneurysms, thrombin injection under sonographic guidance is a quick and effective method of therapy. Failures and complications are infrequent. At our institution, sonographically guided thrombin injection has replaced compression repair.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

AJR Am J Roentgenol

DOI

ISSN

0361-803X

Publication Date

August 2001

Volume

177

Issue

2

Start / End Page

309 / 316

Location

United States

Related Subject Headings

  • Ultrasonography, Interventional
  • Thrombin
  • Nuclear Medicine & Medical Imaging
  • Male
  • Iatrogenic Disease
  • Humans
  • Hemostatics
  • Femoral Artery
  • Female
  • Cattle
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Paulson, E. K., Nelson, R. C., Mayes, C. E., Sheafor, D. H., Sketch, M. H., & Kliewer, M. A. (2001). Sonographically guided thrombin injection of iatrogenic femoral pseudoaneurysms: further experience of a single institution. AJR Am J Roentgenol, 177(2), 309–316. https://doi.org/10.2214/ajr.177.2.1770309
Paulson, E. K., R. C. Nelson, C. E. Mayes, D. H. Sheafor, M. H. Sketch, and M. A. Kliewer. “Sonographically guided thrombin injection of iatrogenic femoral pseudoaneurysms: further experience of a single institution.AJR Am J Roentgenol 177, no. 2 (August 2001): 309–16. https://doi.org/10.2214/ajr.177.2.1770309.
Paulson EK, Nelson RC, Mayes CE, Sheafor DH, Sketch MH, Kliewer MA. Sonographically guided thrombin injection of iatrogenic femoral pseudoaneurysms: further experience of a single institution. AJR Am J Roentgenol. 2001 Aug;177(2):309–16.
Paulson, E. K., et al. “Sonographically guided thrombin injection of iatrogenic femoral pseudoaneurysms: further experience of a single institution.AJR Am J Roentgenol, vol. 177, no. 2, Aug. 2001, pp. 309–16. Pubmed, doi:10.2214/ajr.177.2.1770309.
Paulson EK, Nelson RC, Mayes CE, Sheafor DH, Sketch MH, Kliewer MA. Sonographically guided thrombin injection of iatrogenic femoral pseudoaneurysms: further experience of a single institution. AJR Am J Roentgenol. 2001 Aug;177(2):309–316.

Published In

AJR Am J Roentgenol

DOI

ISSN

0361-803X

Publication Date

August 2001

Volume

177

Issue

2

Start / End Page

309 / 316

Location

United States

Related Subject Headings

  • Ultrasonography, Interventional
  • Thrombin
  • Nuclear Medicine & Medical Imaging
  • Male
  • Iatrogenic Disease
  • Humans
  • Hemostatics
  • Femoral Artery
  • Female
  • Cattle