Skip to main content
Journal cover image

Sensitivity and resolution in 3D NMR microscopy of the lung with hyperpolarized noble gases.

Publication ,  Journal Article
Möller, HE; Chen, XJ; Chawla, MS; Cofer, GP; Driehuys, B; Hedlund, LW; Suddarth, SA; Johnson, GA
Published in: Magn Reson Med
April 1999

Three-dimensional magnetic resonance images of the guinea pig lung were acquired in vivo using hyperpolarized (HP) noble gases and radial projection encoding (PE). Results obtained with 3He (voxel size 17 microl) demonstrated high image quality showing airway structure down to the 5th or 6th generations. Signal-to-noise ratios (SNRs) of 129Xe images (voxel size 40 microl) were lower by about 1 order of magnitude as a consequence of the smaller gyromagnetic ratio, a more rapid relaxation in the gas reservoir, and lower polarization and isotope abundance. Comparison between experimentally obtained SNRs and results from calculations based on a model that accounts for the three-dimensional PE acquisition scheme and the non-equilibrium situation in HP gas imaging yielded excellent agreement for small flip angles. A theoretical examination of the potential resolution in HP gas MR microscopy of the lungs suggests that in vivo visualization of alveolar clusters distal to respiratory bronchioles may be possible.

Duke Scholars

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

April 1999

Volume

41

Issue

4

Start / End Page

800 / 808

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Nuclear Medicine & Medical Imaging
  • Noble Gases
  • Models, Theoretical
  • Microscopy
  • Magnetic Resonance Imaging
  • Lung
  • Guinea Pigs
  • Animals
  • 4003 Biomedical engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Möller, H. E., Chen, X. J., Chawla, M. S., Cofer, G. P., Driehuys, B., Hedlund, L. W., … Johnson, G. A. (1999). Sensitivity and resolution in 3D NMR microscopy of the lung with hyperpolarized noble gases. Magn Reson Med, 41(4), 800–808. https://doi.org/10.1002/(sici)1522-2594(199904)41:4<800::aid-mrm20>3.0.co;2-k
Möller, H. E., X. J. Chen, M. S. Chawla, G. P. Cofer, B. Driehuys, L. W. Hedlund, S. A. Suddarth, and G. A. Johnson. “Sensitivity and resolution in 3D NMR microscopy of the lung with hyperpolarized noble gases.Magn Reson Med 41, no. 4 (April 1999): 800–808. https://doi.org/10.1002/(sici)1522-2594(199904)41:4<800::aid-mrm20>3.0.co;2-k.
Möller HE, Chen XJ, Chawla MS, Cofer GP, Driehuys B, Hedlund LW, et al. Sensitivity and resolution in 3D NMR microscopy of the lung with hyperpolarized noble gases. Magn Reson Med. 1999 Apr;41(4):800–8.
Möller, H. E., et al. “Sensitivity and resolution in 3D NMR microscopy of the lung with hyperpolarized noble gases.Magn Reson Med, vol. 41, no. 4, Apr. 1999, pp. 800–08. Pubmed, doi:10.1002/(sici)1522-2594(199904)41:4<800::aid-mrm20>3.0.co;2-k.
Möller HE, Chen XJ, Chawla MS, Cofer GP, Driehuys B, Hedlund LW, Suddarth SA, Johnson GA. Sensitivity and resolution in 3D NMR microscopy of the lung with hyperpolarized noble gases. Magn Reson Med. 1999 Apr;41(4):800–808.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

April 1999

Volume

41

Issue

4

Start / End Page

800 / 808

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Nuclear Medicine & Medical Imaging
  • Noble Gases
  • Models, Theoretical
  • Microscopy
  • Magnetic Resonance Imaging
  • Lung
  • Guinea Pigs
  • Animals
  • 4003 Biomedical engineering