Bilateral retropharyngeal parathyroid hyperplasia detected with 4D multidetector row CT.
Publication
, Journal Article
Welling, RD; Olson, JA; Kranz, PG; Eastwood, JD; Hoang, JK
Published in: AJNR Am J Neuroradiol
May 2011
We present a case of bilateral retropharyngeal parathyroid hyperplasia detected with 4D-CT in a patient with persistent primary hyperparathyroidism and failed neck exploration. We discuss the embryologic basis of ectopic retropharyngeal parathyroid adenomas and hyperplasia and the utility of 4D-CT in their localization for surgical planning.
Duke Scholars
Published In
AJNR Am J Neuroradiol
DOI
EISSN
1936-959X
Publication Date
May 2011
Volume
32
Issue
5
Start / End Page
E80 / E82
Location
United States
Related Subject Headings
- Tomography, X-Ray Computed
- Respiratory-Gated Imaging Techniques
- Pharyngeal Neoplasms
- Parathyroid Neoplasms
- Nuclear Medicine & Medical Imaging
- Neoplasms, Multiple Primary
- Middle Aged
- Imaging, Three-Dimensional
- Humans
- Female
Citation
APA
Chicago
ICMJE
MLA
NLM
Welling, R. D., Olson, J. A., Kranz, P. G., Eastwood, J. D., & Hoang, J. K. (2011). Bilateral retropharyngeal parathyroid hyperplasia detected with 4D multidetector row CT. AJNR Am J Neuroradiol, 32(5), E80–E82. https://doi.org/10.3174/ajnr.A2104
Welling, R. D., J. A. Olson, P. G. Kranz, J. D. Eastwood, and J. K. Hoang. “Bilateral retropharyngeal parathyroid hyperplasia detected with 4D multidetector row CT.” AJNR Am J Neuroradiol 32, no. 5 (May 2011): E80–82. https://doi.org/10.3174/ajnr.A2104.
Welling RD, Olson JA, Kranz PG, Eastwood JD, Hoang JK. Bilateral retropharyngeal parathyroid hyperplasia detected with 4D multidetector row CT. AJNR Am J Neuroradiol. 2011 May;32(5):E80–2.
Welling, R. D., et al. “Bilateral retropharyngeal parathyroid hyperplasia detected with 4D multidetector row CT.” AJNR Am J Neuroradiol, vol. 32, no. 5, May 2011, pp. E80–82. Pubmed, doi:10.3174/ajnr.A2104.
Welling RD, Olson JA, Kranz PG, Eastwood JD, Hoang JK. Bilateral retropharyngeal parathyroid hyperplasia detected with 4D multidetector row CT. AJNR Am J Neuroradiol. 2011 May;32(5):E80–E82.
Published In
AJNR Am J Neuroradiol
DOI
EISSN
1936-959X
Publication Date
May 2011
Volume
32
Issue
5
Start / End Page
E80 / E82
Location
United States
Related Subject Headings
- Tomography, X-Ray Computed
- Respiratory-Gated Imaging Techniques
- Pharyngeal Neoplasms
- Parathyroid Neoplasms
- Nuclear Medicine & Medical Imaging
- Neoplasms, Multiple Primary
- Middle Aged
- Imaging, Three-Dimensional
- Humans
- Female