A technique optimization protocol and the potential for dose reduction in digital mammography.

Publication ,  Journal Article
Ranger, NT; Lo, JY; Samei, E
Published in: Med Phys
March 2010

Digital mammography requires revisiting techniques that have been optimized for prior screen/film mammography systems. The objective of the study was to determine optimized radiographic technique for a digital mammography system and demonstrate the potential for dose reduction in comparison to the clinically established techniques based on screen- film. An objective figure of merit (FOM) was employed to evaluate a direct-conversion amorphous selenium (a-Se) FFDM system (Siemens Mammomat Novation(DR), Siemens AG Medical Solutions, Erlangen, Germany) and was derived from the quotient of the squared signal-difference-to-noise ratio to mean glandular dose, for various combinations of technique factors and breast phantom configurations including kilovoltage settings (23-35 kVp), target/filter combinations (Mo-Mo and W-Rh), breast-equivalent plastic in various thicknesses (2-8 cm) and densities (100% adipose, 50% adipose/50% glandular, and 100% glandular), and simulated mass and calcification lesions. When using a W-Rh spectrum, the optimized FOM results for the simulated mass and calcification lesions showed highly consistent trends with kVp for each combination of breast density and thickness. The optimized kVp ranged from 26 kVp for 2 cm 100% adipose breasts to 30 kVp for 8 cm 100% glandular breasts. The use of the optimized W-Rh technique compared to standard Mo-Mo techniques provided dose savings ranging from 9% for 2 cm thick, 100% adipose breasts, to 63% for 6 cm thick, 100% glandular breasts, and for breasts with a 50% adipose/50% glandular composition, from 12% for 2 cm thick breasts up to 57% for 8 cm thick breasts.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

March 2010

Volume

37

Issue

3

Start / End Page

962 / 969

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiographic Image Interpretation, Computer-Assisted
  • Radiographic Image Enhancement
  • Radiation Protection
  • Radiation Dosage
  • Quality Control
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Mammography
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ranger, N. T., Lo, J. Y., & Samei, E. (2010). A technique optimization protocol and the potential for dose reduction in digital mammography. Med Phys, 37(3), 962–969. https://doi.org/10.1118/1.3276732
Ranger, Nicole T., Joseph Y. Lo, and Ehsan Samei. “A technique optimization protocol and the potential for dose reduction in digital mammography.Med Phys 37, no. 3 (March 2010): 962–69. https://doi.org/10.1118/1.3276732.
Ranger, Nicole T., et al. “A technique optimization protocol and the potential for dose reduction in digital mammography.Med Phys, vol. 37, no. 3, Mar. 2010, pp. 962–69. Pubmed, doi:10.1118/1.3276732.
Ranger NT, Lo JY, Samei E. A technique optimization protocol and the potential for dose reduction in digital mammography. Med Phys. 2010 Mar;37(3):962–969.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

March 2010

Volume

37

Issue

3

Start / End Page

962 / 969

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiographic Image Interpretation, Computer-Assisted
  • Radiographic Image Enhancement
  • Radiation Protection
  • Radiation Dosage
  • Quality Control
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Mammography