Skip to main content
release_alert
Welcome to the new Scholars 3.0! Read about new features and let us know what you think.
cancel
Journal cover image

Applied PEEP during pressure support reduces the inspiratory threshold load of intrinsic PEEP.

Publication ,  Journal Article
MacIntyre, NR; Cheng, KC; McConnell, R
Published in: Chest
January 1997

OBJECTIVES: Mechanical ventilation in patients with obstructive airway disease (OAD) is associated with the development of dynamic hyperinflation and intrinsic positive end-expiratory pressure (PEEPi). One of the effects of this form of PEEPi is to act as an inspiratory threshold load that can produce ineffective breath triggering, dyspnea, and muscle fatigue. Recently it has been shown that applying PEEP in the ventilator circuit can reduce this imposed triggering load. We wished to investigate this further by studying patients with OAD being weaned with pressure support (PS) ventilation. Our first objective was to determine the prevalence and magnitude of this form of PEEPi in OAD patients who were clinically judged to be capable of triggering mechanical ventilatory breaths. Our second objective was to attempt to reduce the triggering load by applying circuit PEEP and then observe the response of patient-ventilator interactions during the patient-triggered, pressure-limited PS breath. DESIGN: Thirteen random patients with OAD who were receiving PS ventilation were studied by measuring airway pressures, airway gas flow, baseline esophageal pressure, esophageal pressure time products (PTP), and esophageal pressure changes before ventilator gas delivery began (delta Pes taken to represent PEEPi). Measurements were made at baseline and after stepwise increases in circuit PEEP up to the PEEPi. RESULTS: We found measurable PEEPi in all patients (average +/- SD of 9.54 +/- 4.3 cm H2O) and it was > 10 cm H2O in seven patients. As would be predicted, we observed progressive reductions in PEEPi as applied PEEP was given. We also observed that the component of patient effort (PTP) related to overcoming PEEPi also decreased, but the PTP related to tidal volume (VT) did not. The VT associated with the set PS thus did not change with application of PEEP, nor did the breathing frequency. CONCLUSION: PEEPi is common in OAD patients receiving mechanical ventilatory support. The imposed triggering load from PEEPi can be offset to large extent by circuit PEEP approaching the baseline PEEPi. Although total patient effort substantially falls with applied PEEP, the patient effort that combine with PS to effect VT does not.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Chest

DOI

ISSN

0012-3692

Publication Date

January 1997

Volume

111

Issue

1

Start / End Page

188 / 193

Location

United States

Related Subject Headings

  • Ventilator Weaning
  • Tidal Volume
  • Respiratory System
  • Respiratory Muscles
  • Positive-Pressure Respiration
  • Middle Aged
  • Male
  • Lung Diseases, Obstructive
  • Inspiratory Capacity
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
MacIntyre, N. R., Cheng, K. C., & McConnell, R. (1997). Applied PEEP during pressure support reduces the inspiratory threshold load of intrinsic PEEP. Chest, 111(1), 188–193. https://doi.org/10.1378/chest.111.1.188
MacIntyre, N. R., K. C. Cheng, and R. McConnell. “Applied PEEP during pressure support reduces the inspiratory threshold load of intrinsic PEEP.Chest 111, no. 1 (January 1997): 188–93. https://doi.org/10.1378/chest.111.1.188.
MacIntyre NR, Cheng KC, McConnell R. Applied PEEP during pressure support reduces the inspiratory threshold load of intrinsic PEEP. Chest. 1997 Jan;111(1):188–93.
MacIntyre, N. R., et al. “Applied PEEP during pressure support reduces the inspiratory threshold load of intrinsic PEEP.Chest, vol. 111, no. 1, Jan. 1997, pp. 188–93. Pubmed, doi:10.1378/chest.111.1.188.
MacIntyre NR, Cheng KC, McConnell R. Applied PEEP during pressure support reduces the inspiratory threshold load of intrinsic PEEP. Chest. 1997 Jan;111(1):188–193.
Journal cover image

Published In

Chest

DOI

ISSN

0012-3692

Publication Date

January 1997

Volume

111

Issue

1

Start / End Page

188 / 193

Location

United States

Related Subject Headings

  • Ventilator Weaning
  • Tidal Volume
  • Respiratory System
  • Respiratory Muscles
  • Positive-Pressure Respiration
  • Middle Aged
  • Male
  • Lung Diseases, Obstructive
  • Inspiratory Capacity
  • Humans