Jet ventilation at 100 breaths per minute in adult respiratory failure.

Publication ,  Journal Article
MacIntyre, NR; Follett, JV; Deitz, JL; Lawlor, BR
Published in: Am Rev Respir Dis
November 1986

To compare the ventilation and oxygenation capabilities of jet ventilation at 100 breaths per minute with those of conventional mechanical ventilation (CMV) in adults with respiratory failure, we performed a 2- to 3-h cross-over trial of jet ventilation in 65 stable patients requiring mechanical ventilation. Jet ventilation was delivered with an inspiratory time of 0.2 s through a 1.62-mm injector cannula attached to the proximal endotracheal tube. Drive pressure was adjusted to approximate the arterial PaCO2 on CMV. Measurements of arterial blood gases, peak and mean airway pressures (Paw), blood pressure (BP), and heart rate (HR) were recorded during baseline CMV, after every 30-min period during jet ventilation, and again 30 min after returning the patient to CMV. For analysis, patients were divided into 4 clinical and radiographic patterns: diffuse parenchymal disease (n = 22), focal parenchymal disease (n = 18), obstructive airway disease (n = 6), and nonpulmonary disease (n = 19). Jet ventilation "failures" were characterized by significantly higher minute ventilation requirements, higher levels of PaCO2, higher airway pressures, and smaller PaO2/FIO2 ratios on CMV as compared to the 58 ventilatory "successes." In the ventilatory "successes," peak Paw was significantly lower, but mean Paw, PaCO2, PaO2, FIO2, BP, and HR were not significantly different with jet ventilation as compared to CMV. Moreover, in this ventilatory success group, patients with an increase in the PaO2/FIO2 during jet ventilation were not significantly different from patients with a decrease in PO2/FIO2 in terms of clinical characteristics, ventilation requirements, or gas exchange capabilities on CMV.(ABSTRACT TRUNCATED AT 250 WORDS)

Duke Scholars

Published In

Am Rev Respir Dis

DOI

ISSN

0003-0805

Publication Date

November 1986

Volume

134

Issue

5

Start / End Page

897 / 901

Location

United States

Related Subject Headings

  • Respiratory Insufficiency
  • Respiration, Artificial
  • Positive-Pressure Respiration
  • Middle Aged
  • Humans
  • Aged, 80 and over
  • Aged
  • Adult
  • Adolescent
 

Citation

APA
Chicago
ICMJE
MLA
NLM
MacIntyre, N. R., Follett, J. V., Deitz, J. L., & Lawlor, B. R. (1986). Jet ventilation at 100 breaths per minute in adult respiratory failure. Am Rev Respir Dis, 134(5), 897–901. https://doi.org/10.1164/arrd.1986.134.5.897
MacIntyre, N. R., J. V. Follett, J. L. Deitz, and B. R. Lawlor. “Jet ventilation at 100 breaths per minute in adult respiratory failure.Am Rev Respir Dis 134, no. 5 (November 1986): 897–901. https://doi.org/10.1164/arrd.1986.134.5.897.
MacIntyre NR, Follett JV, Deitz JL, Lawlor BR. Jet ventilation at 100 breaths per minute in adult respiratory failure. Am Rev Respir Dis. 1986 Nov;134(5):897–901.
MacIntyre, N. R., et al. “Jet ventilation at 100 breaths per minute in adult respiratory failure.Am Rev Respir Dis, vol. 134, no. 5, Nov. 1986, pp. 897–901. Pubmed, doi:10.1164/arrd.1986.134.5.897.
MacIntyre NR, Follett JV, Deitz JL, Lawlor BR. Jet ventilation at 100 breaths per minute in adult respiratory failure. Am Rev Respir Dis. 1986 Nov;134(5):897–901.

Published In

Am Rev Respir Dis

DOI

ISSN

0003-0805

Publication Date

November 1986

Volume

134

Issue

5

Start / End Page

897 / 901

Location

United States

Related Subject Headings

  • Respiratory Insufficiency
  • Respiration, Artificial
  • Positive-Pressure Respiration
  • Middle Aged
  • Humans
  • Aged, 80 and over
  • Aged
  • Adult
  • Adolescent