Skip to main content
Journal cover image

Computer-assisted tibia preparation for total ankle arthroplasty: a cadaveric study.

Publication ,  Journal Article
Adams, SB; Spritzer, CE; Hofstaetter, SG; Jakoi, AM; Pietrobon, R; Nunley, JA; Easley, ME
Published in: Int J Med Robot
December 2007

BACKGROUND: Most surgeons performing total ankle arthroplasty (TAA) suggest that accurate tibial preparation perpendicular to the tibial shaft axis improves outcomes. Recent studies demonstrate that computerized surgical navigation significantly improves the accuracy of tibial preparation in total knee arthroplasty (TKA). METHODS: We performed the tibial preparation for TAA in seven matched pairs of cadaver lower extremities. One set of matched pairs was prepared using the conventional external tibial alignment guide/cutting block from the Scandanavian Total Ankle Replacement system (STAR, Waldemar Link GmbH & Co., Hamburg, Germany) under fluoroscopic guidance. The second set of matched pairs was prepared using the VectorVision((R)) navigation system (BrainLAB, Munich, Germany), with currently available computed tomography (CT)-based TKA software. Pre-operative CT data were used to assess the tibial mechanical axis. In both groups, accuracy of the tibial plafond preparation relative to the tibial shaft axis in both the coronal and sagittal planes was determined by fluoroscopic, radiographic and CT analysis. RESULTS: Mean values of the tibial cut for the set of matched-pair tibiae prepared by the conventional surgical method ranged across the three imaging assessment techniques in the ranges 89.3-89.6 degrees (coronal plane, anteroposterior) and 90.3-90.4 degrees (sagittal plane, lateral). For the computer-navigated set, the values were 89.7-89.9 degrees (coronal) and 89.1-89.4 degrees (sagittal). Comparison between the conventional and computer-navigated tibial measurements were not different at the 95% confidence interval (CI) for CT, fluoroscopy or radiographic assessments. CONCLUSIONS: Our results demonstrate that accuracy of TAA tibial preparation using computer-navigation equals that of the conventional technique performed by a foot and ankle surgeon experienced in TAA. We anticipate that this investigation will encourage the development of computer-navigation applications specific to TAA, with the potential of improving accuracy over conventional methods.

Duke Scholars

Published In

Int J Med Robot

DOI

EISSN

1478-596X

Publication Date

December 2007

Volume

3

Issue

4

Start / End Page

336 / 340

Location

England

Related Subject Headings

  • Surgery, Computer-Assisted
  • Surgery
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiography, Interventional
  • Humans
  • Cadaver
  • Arthroplasty
  • Ankle Joint
  • 4601 Applied computing
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Adams, S. B., Spritzer, C. E., Hofstaetter, S. G., Jakoi, A. M., Pietrobon, R., Nunley, J. A., & Easley, M. E. (2007). Computer-assisted tibia preparation for total ankle arthroplasty: a cadaveric study. Int J Med Robot, 3(4), 336–340. https://doi.org/10.1002/rcs.163
Adams, Samuel B., Charles E. Spritzer, Stefan G. Hofstaetter, Andre M. Jakoi, Ricardo Pietrobon, James A. Nunley, and Mark E. Easley. “Computer-assisted tibia preparation for total ankle arthroplasty: a cadaveric study.Int J Med Robot 3, no. 4 (December 2007): 336–40. https://doi.org/10.1002/rcs.163.
Adams SB, Spritzer CE, Hofstaetter SG, Jakoi AM, Pietrobon R, Nunley JA, et al. Computer-assisted tibia preparation for total ankle arthroplasty: a cadaveric study. Int J Med Robot. 2007 Dec;3(4):336–40.
Adams, Samuel B., et al. “Computer-assisted tibia preparation for total ankle arthroplasty: a cadaveric study.Int J Med Robot, vol. 3, no. 4, Dec. 2007, pp. 336–40. Pubmed, doi:10.1002/rcs.163.
Adams SB, Spritzer CE, Hofstaetter SG, Jakoi AM, Pietrobon R, Nunley JA, Easley ME. Computer-assisted tibia preparation for total ankle arthroplasty: a cadaveric study. Int J Med Robot. 2007 Dec;3(4):336–340.
Journal cover image

Published In

Int J Med Robot

DOI

EISSN

1478-596X

Publication Date

December 2007

Volume

3

Issue

4

Start / End Page

336 / 340

Location

England

Related Subject Headings

  • Surgery, Computer-Assisted
  • Surgery
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiography, Interventional
  • Humans
  • Cadaver
  • Arthroplasty
  • Ankle Joint
  • 4601 Applied computing