Hemolytic transfusion reactions caused by failure of commercial antiglobulin reagents to detect complement.
Publication
, Journal Article
Sherwood, GK; Haynes, BF; Rosse, WF
Published in: Transfusion
1976
Two definite acute hemolytic transfusion reactions occurred in a patient with chronic myelogenous leukemia in blastic crisis. Both suspect units were entirely compatible by routine crossmatch using commercial antiblobulin sera. However, both units were clearly incompatible using our own specific anti-C3 antiserum in the antiglobulin reaction phase of the crossmatch. Subsequently it was possible to predict in vivo compatibility using our anti-C3 antiserum in vitro. This case adds new evidence for the inadequacy of anticomplement activity in commercial antisera.
Duke Scholars
Published In
Transfusion
DOI
ISSN
0041-1132
Publication Date
1976
Volume
16
Issue
5
Start / End Page
417 / 420
Location
United States
Related Subject Headings
- Transfusion Reaction
- Male
- Lutheran Blood-Group System
- Leukemia, Myeloid
- Isoantibodies
- Immune Sera
- Humans
- Hemolysis
- Coombs Test
- Complement System Proteins
Citation
APA
Chicago
ICMJE
MLA
NLM
Sherwood, G. K., Haynes, B. F., & Rosse, W. F. (1976). Hemolytic transfusion reactions caused by failure of commercial antiglobulin reagents to detect complement. Transfusion, 16(5), 417–420. https://doi.org/10.1046/j.1537-2995.1976.16577039295.x
Sherwood, G. K., B. F. Haynes, and W. F. Rosse. “Hemolytic transfusion reactions caused by failure of commercial antiglobulin reagents to detect complement.” Transfusion 16, no. 5 (1976): 417–20. https://doi.org/10.1046/j.1537-2995.1976.16577039295.x.
Sherwood GK, Haynes BF, Rosse WF. Hemolytic transfusion reactions caused by failure of commercial antiglobulin reagents to detect complement. Transfusion. 1976;16(5):417–20.
Sherwood, G. K., et al. “Hemolytic transfusion reactions caused by failure of commercial antiglobulin reagents to detect complement.” Transfusion, vol. 16, no. 5, 1976, pp. 417–20. Pubmed, doi:10.1046/j.1537-2995.1976.16577039295.x.
Sherwood GK, Haynes BF, Rosse WF. Hemolytic transfusion reactions caused by failure of commercial antiglobulin reagents to detect complement. Transfusion. 1976;16(5):417–420.

Published In
Transfusion
DOI
ISSN
0041-1132
Publication Date
1976
Volume
16
Issue
5
Start / End Page
417 / 420
Location
United States
Related Subject Headings
- Transfusion Reaction
- Male
- Lutheran Blood-Group System
- Leukemia, Myeloid
- Isoantibodies
- Immune Sera
- Humans
- Hemolysis
- Coombs Test
- Complement System Proteins