Comparison of interlaboratory variation in absolute T-cell counts by single-platform and optimized dual-platform methods.

Publication ,  Journal Article
Hultin, LE; Chow, M; Jamieson, BD; O'Gorman, MRG; Menendez, FA; Borowski, L; Denny, TN; Margolick, JB
Published in: Cytometry B Clin Cytom
May 2010

BACKGROUND: Previous studies have reported that the adoption of a single-platform flow cytometry cell counting method resulted in lower interlaboratory variation in absolute T cell counts as compared to predicate dual-platform flow cytometry methods which incorporate independent automated lymphocyte counts (Schnizlein-Bick et al., Clin Diagn Lab Immunol 2000;7:336-343; Reimann et al., Clin Diagn Lab Immunol 2000;7:344-351). In the present study, we asked whether use of a single-platform method could reduce variation in absolute cell counts across the laboratories in the Multicenter AIDS Cohort Study (MACS) (n = 4), as suggested by the studies cited. METHODS: Identical study samples were shipped overnight to the MACS laboratories either by the National Institute of Allergy and Infectious Diseases, Division of AIDS Immunology Quality Assessment (NIAID- IQA) proficiency-testing program (n = 14), or by the Los Angeles site of the MACS (n = 10). For each sample, two tubes of blood were received; one was used for an automated complete blood count and differential, and the other for flow cytometry. The latter was performed using both our current dual-platform method (three-color CD45 gating and automated hematology) and the single-platform method (with TruCOUNT beads to generate the absolute counts). RESULTS: The median percent coefficients of variation (%CVs) for the dual-platform and single-platform methods were 6.6 and 9.9, respectively, for CD4 T cell counts, and 5.9 and 8.5, respectively, for CD8 T cell counts (n = 24). These differences were not statistically significant. The differences in absolute T-cell counts between the MACS sites and the median of all laboratories participating in the NIAID-IQA were smaller for the dual-platform than for single-platform absolute count method. CONCLUSION: In contrast to previous reports, we did not observe lower interlaboratory variation across the MACS sites for single-platform absolute lymphocyte subset counting relative to dual-platform methods. This result may be at least partly explained by the lower interlaboratory variation with the optimized dual-platform method in this study relative to the previous reports.

Duke Scholars

Published In

Cytometry B Clin Cytom

DOI

EISSN

1552-4957

Publication Date

May 2010

Volume

78

Issue

3

Start / End Page

194 / 200

Location

United States

Related Subject Headings

  • Reproducibility of Results
  • Reference Standards
  • Lymphocyte Count
  • Laboratories
  • Immunology
  • Humans
  • Flow Cytometry
  • Cohort Studies
  • 3201 Cardiovascular medicine and haematology
  • 0601 Biochemistry and Cell Biology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hultin, L. E., Chow, M., Jamieson, B. D., O’Gorman, M. R. G., Menendez, F. A., Borowski, L., … Margolick, J. B. (2010). Comparison of interlaboratory variation in absolute T-cell counts by single-platform and optimized dual-platform methods. Cytometry B Clin Cytom, 78(3), 194–200. https://doi.org/10.1002/cyto.b.20500
Hultin, Lance E., Marianne Chow, Beth D. Jamieson, Maurice R. G. O’Gorman, Frederick A. Menendez, Luann Borowski, Thomas N. Denny, and Joseph B. Margolick. “Comparison of interlaboratory variation in absolute T-cell counts by single-platform and optimized dual-platform methods.Cytometry B Clin Cytom 78, no. 3 (May 2010): 194–200. https://doi.org/10.1002/cyto.b.20500.
Hultin LE, Chow M, Jamieson BD, O’Gorman MRG, Menendez FA, Borowski L, et al. Comparison of interlaboratory variation in absolute T-cell counts by single-platform and optimized dual-platform methods. Cytometry B Clin Cytom. 2010 May;78(3):194–200.
Hultin, Lance E., et al. “Comparison of interlaboratory variation in absolute T-cell counts by single-platform and optimized dual-platform methods.Cytometry B Clin Cytom, vol. 78, no. 3, May 2010, pp. 194–200. Pubmed, doi:10.1002/cyto.b.20500.
Hultin LE, Chow M, Jamieson BD, O’Gorman MRG, Menendez FA, Borowski L, Denny TN, Margolick JB. Comparison of interlaboratory variation in absolute T-cell counts by single-platform and optimized dual-platform methods. Cytometry B Clin Cytom. 2010 May;78(3):194–200.
Journal cover image

Published In

Cytometry B Clin Cytom

DOI

EISSN

1552-4957

Publication Date

May 2010

Volume

78

Issue

3

Start / End Page

194 / 200

Location

United States

Related Subject Headings

  • Reproducibility of Results
  • Reference Standards
  • Lymphocyte Count
  • Laboratories
  • Immunology
  • Humans
  • Flow Cytometry
  • Cohort Studies
  • 3201 Cardiovascular medicine and haematology
  • 0601 Biochemistry and Cell Biology