This paper describes an automated procedure for creating detailed patient-specific pediatric dosimetry phantoms from a small set of segmented organs in a child's CT scan. The algorithm involves full body mappings from adult template to pediatric images using multichannel large deformation diffeomorphic metric mapping (MC-LDDMM). The parallel implementation and performance of MC-LDDMM for this application is studied here for a sample of 4 pediatric patients, and from 1 to 24 processors. 93.84% of computation time is parallelized, and the efficiency of parallelization remains high until more than 8 processors are used. The performance of the algorithm was validated on a set of 24 male and 18 female pediatric patients. It was found to be accurate typically to within 1-2 voxels (2-4 mm) and robust across this large and variable data set.

Duke Scholars

Published In

Int J Biomed Imaging

DOI

EISSN

1687-4196

Publication Date

2011

Volume

2011

Start / End Page

481064

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tward, D. J., Ceritoglu, C., Kolasny, A., Sturgeon, G. M., Segars, W. P., Miller, M. I., & Ratnanather, J. T. (2011). Patient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body. Int J Biomed Imaging, 2011, 481064. https://doi.org/10.1155/2011/481064
Tward, Daniel J., Can Ceritoglu, Anthony Kolasny, Gregory M. Sturgeon, W Paul Segars, Michael I. Miller, and J Tilak Ratnanather. “Patient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body.Int J Biomed Imaging 2011 (2011): 481064. https://doi.org/10.1155/2011/481064.
Tward DJ, Ceritoglu C, Kolasny A, Sturgeon GM, Segars WP, Miller MI, et al. Patient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body. Int J Biomed Imaging. 2011;2011:481064.
Tward, Daniel J., et al. “Patient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body.Int J Biomed Imaging, vol. 2011, 2011, p. 481064. Pubmed, doi:10.1155/2011/481064.
Tward DJ, Ceritoglu C, Kolasny A, Sturgeon GM, Segars WP, Miller MI, Ratnanather JT. Patient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body. Int J Biomed Imaging. 2011;2011:481064.

Published In

Int J Biomed Imaging

DOI

EISSN

1687-4196

Publication Date

2011

Volume

2011

Start / End Page

481064

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging