Truncated sinc slice excitation for 31P spectroscopic imaging.

Publication ,  Journal Article
MacFall, JR; Charles, HC; Prost, R
Published in: Magn Reson Imaging
1990

The shortest possible delay (Td) between slice selection and data acquisition is important for producing high quality 31P spectra. In single slice multivoxel spectroscopic imaging, conventional excitation using sinc-shaped rf pulses within typical gradient limitations can have values of Td that lead to significant spectral distortion and loss of signal. Truncated sinc excitation, which ends the excitation close to the center of the main rf lobe has been suggested for MR angiographic applications to produce short values of Td. In this work, the slice profiles, spectral signal-to-noise ratio (SNR) and spectral distortions are compared using the minimum delay achievable on a commercial MRI system for conventional 'sinc' rf excitation and truncated sinc excitation. Slice profiles are calculated using the Bloch equations and measured with a phantom. SNR and spectral distortions are evaluated from whole slice spectra on a human volunteer. On an MRI system with 1 G/cm gradients (0.5 msec risetime), for a 2.5-cm slice at 31P frequencies, conventional excitation can be adjusted to achieve Td = 2.5 msec while truncated sinc excitation yields Td = 1.5 msec. The truncated sinc excitation's shorter value of Td leads to much smaller spectral distortions, but its slice profile has "dispersive tails" which increase as more of the rf is truncated. Slice profile corrected SNR for the beta-ATP peak of 31P on a human volunteer is equivalent for both sequences while, qualitatively, in the PDE region the truncated sinc approach has improved SNR.

Duke Scholars

Published In

Magn Reson Imaging

DOI

ISSN

0730-725X

Publication Date

1990

Volume

8

Issue

5

Start / End Page

619 / 624

Location

Netherlands

Related Subject Headings

  • Time Factors
  • Phosphorus
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Spectroscopy
  • Image Enhancement
  • Humans
  • Brain
  • 3202 Clinical sciences
  • 1702 Cognitive Sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
MacFall, J. R., Charles, H. C., & Prost, R. (1990). Truncated sinc slice excitation for 31P spectroscopic imaging. Magn Reson Imaging, 8(5), 619–624. https://doi.org/10.1016/0730-725x(90)90140-w
MacFall, J. R., H. C. Charles, and R. Prost. “Truncated sinc slice excitation for 31P spectroscopic imaging.Magn Reson Imaging 8, no. 5 (1990): 619–24. https://doi.org/10.1016/0730-725x(90)90140-w.
MacFall JR, Charles HC, Prost R. Truncated sinc slice excitation for 31P spectroscopic imaging. Magn Reson Imaging. 1990;8(5):619–24.
MacFall, J. R., et al. “Truncated sinc slice excitation for 31P spectroscopic imaging.Magn Reson Imaging, vol. 8, no. 5, 1990, pp. 619–24. Pubmed, doi:10.1016/0730-725x(90)90140-w.
MacFall JR, Charles HC, Prost R. Truncated sinc slice excitation for 31P spectroscopic imaging. Magn Reson Imaging. 1990;8(5):619–624.
Journal cover image

Published In

Magn Reson Imaging

DOI

ISSN

0730-725X

Publication Date

1990

Volume

8

Issue

5

Start / End Page

619 / 624

Location

Netherlands

Related Subject Headings

  • Time Factors
  • Phosphorus
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Spectroscopy
  • Image Enhancement
  • Humans
  • Brain
  • 3202 Clinical sciences
  • 1702 Cognitive Sciences
  • 1103 Clinical Sciences