Skip to main content

Muscle activity localization with 31P spectroscopy and calculated T2-weighted 1H images.

Publication ,  Journal Article
Weidman, ER; Charles, HC; Negro-Vilar, R; Sullivan, MJ; MacFall, JR
Published in: Investigative radiology
April 1991

Using 31P spectroscopy and magnetic resonance imaging (MRI), the authors studied changes in muscle phosphorous metabolites and T2 with isometric knee extension to evaluate the potential role of T2 images in coil placement for exercise spectroscopy studies. Increased signal intensity was visible in active muscles on T2 images after exercise. Calculated T2-weighted values were elevated immediately after exercise in the quadriceps (P less than .01). T2 increases for individual quadricep muscles varied, with the largest changes in the rectus femoris and the least in the vastus lateralis. 31P spectroscopy studies demonstrated similar findings: percent change in T2 correlated positively with inorganic phosphorus to phosphocreatine ratio (Pi/PCr) (r = 0.89, P less than .01) and negatively with pH (r = -0.88, P less than .01). The correlations between imaging and spectroscopy suggest that T2 images may allow more precise placement of phosphorous coils in exercise studies. The heterogeneity of T2 changes within the quadriceps with exercise suggests that assumptions about muscle activity may be misleading. T2 images may provide muscle activity verification for exercise studies.

Published In

Investigative radiology

DOI

EISSN

1536-0210

ISSN

0020-9996

Publication Date

April 1991

Volume

26

Issue

4

Start / End Page

309 / 316

Related Subject Headings

  • Phosphorus
  • Phosphocreatine
  • Nuclear Medicine & Medical Imaging
  • Muscles
  • Muscle Contraction
  • Magnetic Resonance Spectroscopy
  • Leg
  • Isometric Contraction
  • Humans
  • Adult
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Weidman, E. R., Charles, H. C., Negro-Vilar, R., Sullivan, M. J., & MacFall, J. R. (1991). Muscle activity localization with 31P spectroscopy and calculated T2-weighted 1H images. Investigative Radiology, 26(4), 309–316. https://doi.org/10.1097/00004424-199104000-00005
Weidman, E. R., H. C. Charles, R. Negro-Vilar, M. J. Sullivan, and J. R. MacFall. “Muscle activity localization with 31P spectroscopy and calculated T2-weighted 1H images.Investigative Radiology 26, no. 4 (April 1991): 309–16. https://doi.org/10.1097/00004424-199104000-00005.
Weidman ER, Charles HC, Negro-Vilar R, Sullivan MJ, MacFall JR. Muscle activity localization with 31P spectroscopy and calculated T2-weighted 1H images. Investigative radiology. 1991 Apr;26(4):309–16.
Weidman, E. R., et al. “Muscle activity localization with 31P spectroscopy and calculated T2-weighted 1H images.Investigative Radiology, vol. 26, no. 4, Apr. 1991, pp. 309–16. Epmc, doi:10.1097/00004424-199104000-00005.
Weidman ER, Charles HC, Negro-Vilar R, Sullivan MJ, MacFall JR. Muscle activity localization with 31P spectroscopy and calculated T2-weighted 1H images. Investigative radiology. 1991 Apr;26(4):309–316.

Published In

Investigative radiology

DOI

EISSN

1536-0210

ISSN

0020-9996

Publication Date

April 1991

Volume

26

Issue

4

Start / End Page

309 / 316

Related Subject Headings

  • Phosphorus
  • Phosphocreatine
  • Nuclear Medicine & Medical Imaging
  • Muscles
  • Muscle Contraction
  • Magnetic Resonance Spectroscopy
  • Leg
  • Isometric Contraction
  • Humans
  • Adult