A wavelet-based method for removal of out-of-plane structures in digital tomosynthesis.
Publication
, Journal Article
Badea, C; Kolitsi, Z; Pallikarakis, N
Published in: Comput Med Imaging Graph
1998
Reconstructed images in digital tomosynthesis (DTS) are affected by artifacts due to blur from planes other than the fulcrum plane. A wavelet-based method has been developed for the discrimination and subsequent removal of unrelated structures from the reconstructed plane. The approach exploits both the specific pattern of noise in DTS and the spatial locality of the wavelet transformation. The technique was implemented on a DTS clinical protoype system. Experimental evaluation on angiographic types of images demonstrated excellent noise differentiation and elimination. The method is therefore particularly useful for certain medical imaging applications such as vascular DTS imaging.
Duke Scholars
Published In
Comput Med Imaging Graph
DOI
ISSN
0895-6111
Publication Date
1998
Volume
22
Issue
4
Start / End Page
309 / 315
Location
United States
Related Subject Headings
- Tomography, X-Ray
- Sheep
- Radiographic Image Enhancement
- Phantoms, Imaging
- Nuclear Medicine & Medical Imaging
- Lung
- Image Processing, Computer-Assisted
- Humans
- Evaluation Studies as Topic
- Contrast Media
Citation
APA
Chicago
ICMJE
MLA
NLM
Badea, C., Kolitsi, Z., & Pallikarakis, N. (1998). A wavelet-based method for removal of out-of-plane structures in digital tomosynthesis. Comput Med Imaging Graph, 22(4), 309–315. https://doi.org/10.1016/s0895-6111(98)00037-8
Badea, C., Z. Kolitsi, and N. Pallikarakis. “A wavelet-based method for removal of out-of-plane structures in digital tomosynthesis.” Comput Med Imaging Graph 22, no. 4 (1998): 309–15. https://doi.org/10.1016/s0895-6111(98)00037-8.
Badea C, Kolitsi Z, Pallikarakis N. A wavelet-based method for removal of out-of-plane structures in digital tomosynthesis. Comput Med Imaging Graph. 1998;22(4):309–15.
Badea, C., et al. “A wavelet-based method for removal of out-of-plane structures in digital tomosynthesis.” Comput Med Imaging Graph, vol. 22, no. 4, 1998, pp. 309–15. Pubmed, doi:10.1016/s0895-6111(98)00037-8.
Badea C, Kolitsi Z, Pallikarakis N. A wavelet-based method for removal of out-of-plane structures in digital tomosynthesis. Comput Med Imaging Graph. 1998;22(4):309–315.
Published In
Comput Med Imaging Graph
DOI
ISSN
0895-6111
Publication Date
1998
Volume
22
Issue
4
Start / End Page
309 / 315
Location
United States
Related Subject Headings
- Tomography, X-Ray
- Sheep
- Radiographic Image Enhancement
- Phantoms, Imaging
- Nuclear Medicine & Medical Imaging
- Lung
- Image Processing, Computer-Assisted
- Humans
- Evaluation Studies as Topic
- Contrast Media