A novel approach for distortion correction for X-ray image intensifiers.

Publication ,  Journal Article
Soimu, D; Badea, C; Pallikarakis, N
Published in: Comput Med Imaging Graph
2003

Applications of X-ray image intensifiers in medical imaging, include the use of fluoroscopic projection images to generate three-dimensional tomographic reconstructions. Unfortunately, the inherent distortions on the acquired projections deteriorate the quality of the reconstructed tomograms. Distortion correction can be performed using algorithms that can be classified as global or local according to the method used, both having specific advantages and disadvantages. In this work, a novel approach for distortion correction is proposed which, by combining both global and local correction methods allows good image quality in relatively acceptable time. Correction parameters were obtained using a calibration phantom specially designed for this purpose.

Duke Scholars

Published In

Comput Med Imaging Graph

DOI

ISSN

0895-6111

Publication Date

2003

Volume

27

Issue

1

Start / End Page

79 / 85

Location

United States

Related Subject Headings

  • X-Ray Intensifying Screens
  • Radiographic Image Enhancement
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Imaging, Three-Dimensional
  • Humans
  • 4603 Computer vision and multimedia computation
  • 4003 Biomedical engineering
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Soimu, D., Badea, C., & Pallikarakis, N. (2003). A novel approach for distortion correction for X-ray image intensifiers. Comput Med Imaging Graph, 27(1), 79–85. https://doi.org/10.1016/s0895-6111(02)00055-1
Soimu, Delia, Cristian Badea, and Nicolas Pallikarakis. “A novel approach for distortion correction for X-ray image intensifiers.Comput Med Imaging Graph 27, no. 1 (2003): 79–85. https://doi.org/10.1016/s0895-6111(02)00055-1.
Soimu D, Badea C, Pallikarakis N. A novel approach for distortion correction for X-ray image intensifiers. Comput Med Imaging Graph. 2003;27(1):79–85.
Soimu, Delia, et al. “A novel approach for distortion correction for X-ray image intensifiers.Comput Med Imaging Graph, vol. 27, no. 1, 2003, pp. 79–85. Pubmed, doi:10.1016/s0895-6111(02)00055-1.
Soimu D, Badea C, Pallikarakis N. A novel approach for distortion correction for X-ray image intensifiers. Comput Med Imaging Graph. 2003;27(1):79–85.
Journal cover image

Published In

Comput Med Imaging Graph

DOI

ISSN

0895-6111

Publication Date

2003

Volume

27

Issue

1

Start / End Page

79 / 85

Location

United States

Related Subject Headings

  • X-Ray Intensifying Screens
  • Radiographic Image Enhancement
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Imaging, Three-Dimensional
  • Humans
  • 4603 Computer vision and multimedia computation
  • 4003 Biomedical engineering
  • 3202 Clinical sciences
  • 1103 Clinical Sciences