Free-space fluorescence tomography with adaptive sampling based on anatomical information from microCT.

Publication ,  Conference
Zhang, X; Badea, CT; Hood, G; Wetzel, AW; Stiles, JR; Johnson, GA
Published in: Proc SPIE Int Soc Opt Eng
2010

Image reconstruction is one of the main challenges for fluorescence tomography. For in vivo experiments on small animals, in particular, the inhomogeneous optical properties and irregular surface of the animal make free-space image reconstruction challenging because of the difficulties in accurately modeling the forward problem and the finite dynamic range of the photodetector. These two factors are fundamentally limited by the currently available forward models and photonic technologies. Nonetheless, both limitations can be significantly eased using a signal processing approach. We have recently constructed a free-space panoramic fluorescence diffuse optical tomography system to take advantage of co-registered microCT data acquired from the same animal. In this article, we present a data processing strategy that adaptively selects the optical sampling points in the raw 2-D fluorescent CCD images. Specifically, the general sampling area and sampling density are initially specified to create a set of potential sampling points sufficient to cover the region of interest. Based on 3-D anatomical information from the microCT and the fluorescent CCD images, data points are excluded from the set when they are located in an area where either the forward model is known to be problematic (e.g., large wrinkles on the skin) or where the signal is unreliable (e.g., saturated or low signal-to-noise ratio). Parallel Monte Carlo software was implemented to compute the sensitivity function for image reconstruction. Animal experiments were conducted on a mouse cadaver with an artificial fluorescent inclusion. Compared to our previous results using a finite element method, the newly developed parallel Monte Carlo software and the adaptive sampling strategy produced favorable reconstruction results.

Duke Scholars

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

2010

Volume

7757

Issue

775706

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhang, X., Badea, C. T., Hood, G., Wetzel, A. W., Stiles, J. R., & Johnson, G. A. (2010). Free-space fluorescence tomography with adaptive sampling based on anatomical information from microCT. In Proc SPIE Int Soc Opt Eng (Vol. 7757). United States. https://doi.org/10.1117/12.841891
Zhang, Xiaofeng, Cristian T. Badea, Greg Hood, Arthur W. Wetzel, Joel R. Stiles, and G Allan Johnson. “Free-space fluorescence tomography with adaptive sampling based on anatomical information from microCT.” In Proc SPIE Int Soc Opt Eng, Vol. 7757, 2010. https://doi.org/10.1117/12.841891.
Zhang X, Badea CT, Hood G, Wetzel AW, Stiles JR, Johnson GA. Free-space fluorescence tomography with adaptive sampling based on anatomical information from microCT. In: Proc SPIE Int Soc Opt Eng. 2010.
Zhang, Xiaofeng, et al. “Free-space fluorescence tomography with adaptive sampling based on anatomical information from microCT.Proc SPIE Int Soc Opt Eng, vol. 7757, no. 775706, 2010. Pubmed, doi:10.1117/12.841891.
Zhang X, Badea CT, Hood G, Wetzel AW, Stiles JR, Johnson GA. Free-space fluorescence tomography with adaptive sampling based on anatomical information from microCT. Proc SPIE Int Soc Opt Eng. 2010.

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

2010

Volume

7757

Issue

775706

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering