Skip to main content
Journal cover image

Phenylephrine-modulated cardiopulmonary blood flow measured with use of X-ray digital subtraction angiography.

Publication ,  Journal Article
Lin, M; Qi, Y; Chen, AF; Badea, CT; Johnson, GA
Published in: J Pharmacol Toxicol Methods
2011

INTRODUCTION: Cardiopulmonary blood flow is an important indicator of organ function. Limitations in measuring blood flow in live rodents suggest that rapid physiological changes may be overlooked. For instance, relative measurements limit imaging to whole organs or large sections without adequately visualizing vasculature. Additionally, current methods use small samples and invasive techniques that often require killing animals, limiting sampling speed, or both. A recently developed high spatial- and temporal-resolution X-ray digital subtraction angiography (DSA) system visualizes vasculature and measures blood flow in rodents. This study was the first to use this system to measure changes in cardiopulmonary blood flow in rats after administering the vasoconstrictor phenylephrine. METHODS: Cardiopulmonary blood flow and vascular anatomy were assessed in 11 rats before, during, and after recovery from phenylephrine. After acquiring DSA images at 12 time points, a calibrated non-parametric deconvolution technique using singular value decomposition (SVD) was applied to calculate quantitative aortic blood flow in absolute metrics (mL/min). Trans-pulmonary transit time was calculated as the time interval between maximum signal enhancement in the pulmonary trunk and aorta. Pulmonary blood volume was calculated based on the central volume principle. Statistical analysis compared differences in trans-pulmonary blood volume and pressure, and aortic diameter using paired t-tests on baseline, peak, and late-recovery time points. RESULTS: Phenylephrine had dramatic qualitative and quantitative effects on vascular anatomy and blood flow. Major vessels distended significantly (aorta, ~1.2-times baseline) and mean arterial blood pressure increased ~2 times. Pulmonary blood volume, flow, pressure, and aortic diameter were not significantly different between baseline and late recovery, but differences were significant between baseline and peak, as well as peak and recovery time points. DISCUSSION: The DSA system with calibrated SVD technique acquired blood flow measurements every 30s with a high level of regional specificity, thus providing a new option for in vivo functional assessment in small animals.

Duke Scholars

Published In

J Pharmacol Toxicol Methods

DOI

EISSN

1873-488X

Publication Date

2011

Volume

64

Issue

2

Start / End Page

180 / 186

Location

United States

Related Subject Headings

  • Vasoconstrictor Agents
  • Time Factors
  • Rats, Inbred F344
  • Rats
  • Pulmonary Circulation
  • Phenylephrine
  • Pharmacology & Pharmacy
  • Male
  • Blood Pressure
  • Aorta
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lin, M., Qi, Y., Chen, A. F., Badea, C. T., & Johnson, G. A. (2011). Phenylephrine-modulated cardiopulmonary blood flow measured with use of X-ray digital subtraction angiography. J Pharmacol Toxicol Methods, 64(2), 180–186. https://doi.org/10.1016/j.vascn.2011.08.001
Lin, MingDe, Yi Qi, Antonia F. Chen, Cristian T. Badea, and G Allan Johnson. “Phenylephrine-modulated cardiopulmonary blood flow measured with use of X-ray digital subtraction angiography.J Pharmacol Toxicol Methods 64, no. 2 (2011): 180–86. https://doi.org/10.1016/j.vascn.2011.08.001.
Lin M, Qi Y, Chen AF, Badea CT, Johnson GA. Phenylephrine-modulated cardiopulmonary blood flow measured with use of X-ray digital subtraction angiography. J Pharmacol Toxicol Methods. 2011;64(2):180–6.
Lin, MingDe, et al. “Phenylephrine-modulated cardiopulmonary blood flow measured with use of X-ray digital subtraction angiography.J Pharmacol Toxicol Methods, vol. 64, no. 2, 2011, pp. 180–86. Pubmed, doi:10.1016/j.vascn.2011.08.001.
Lin M, Qi Y, Chen AF, Badea CT, Johnson GA. Phenylephrine-modulated cardiopulmonary blood flow measured with use of X-ray digital subtraction angiography. J Pharmacol Toxicol Methods. 2011;64(2):180–186.
Journal cover image

Published In

J Pharmacol Toxicol Methods

DOI

EISSN

1873-488X

Publication Date

2011

Volume

64

Issue

2

Start / End Page

180 / 186

Location

United States

Related Subject Headings

  • Vasoconstrictor Agents
  • Time Factors
  • Rats, Inbred F344
  • Rats
  • Pulmonary Circulation
  • Phenylephrine
  • Pharmacology & Pharmacy
  • Male
  • Blood Pressure
  • Aorta