Skip to main content

4-D micro-CT of the mouse heart.

Publication ,  Journal Article
Badea, CT; Fubara, B; Hedlund, LW; Johnson, GA
Published in: Mol Imaging
2005

PURPOSE: Demonstrate noninvasive imaging methods for in vivo characterization of cardiac structure and function in mice using a micro-CT system that provides high photon fluence rate and integrated motion control. MATERIALS AND METHODS: Simultaneous cardiac- and respiratory-gated micro-CT was performed in C57BL/6 mice during constant intravenous infusion of a conventional iodinated contrast agent (Isovue-370), and after a single intravenous injection of a blood pool contrast agent (Fenestra VC). Multiple phases of the cardiac cycle were reconstructed with contrast to noise and spatial resolution sufficient for quantitative assessment of cardiac function. RESULTS: Contrast enhancement with Isovue-370 increased over time with a maximum of approximately 500 HU (aorta) and 900 HU (kidney cortex). Fenestra VC provided more constant enhancement over 3 hr, with maximum enhancement of approximately 620 HU (aorta) and approximately 90 HU (kidney cortex). The maximum enhancement difference between blood and myocardium in the heart was approximately 250 HU for Isovue-370 and approximately 500 HU for Fenestra VC. In mice with Fenestra VC, volumetric measurements of the left ventricle were performed and cardiac function was estimated by ejection fraction, stroke volume, and cardiac output. CONCLUSION: Image quality with Fenestra VC was sufficient for morphological and functional studies required for a standardized method of cardiac phenotyping of the mouse.

Duke Scholars

Published In

Mol Imaging

DOI

ISSN

1535-3508

Publication Date

2005

Volume

4

Issue

2

Start / End Page

110 / 116

Location

England

Related Subject Headings

  • Tomography, X-Ray Computed
  • Nuclear Medicine & Medical Imaging
  • Mice, Inbred C57BL
  • Mice
  • Iopamidol
  • Iodine
  • Heart
  • Contrast Media
  • Animals
  • 4003 Biomedical engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Badea, C. T., Fubara, B., Hedlund, L. W., & Johnson, G. A. (2005). 4-D micro-CT of the mouse heart. Mol Imaging, 4(2), 110–116. https://doi.org/10.1162/15353500200504187
Badea, Cristian T., Boma Fubara, Laurence W. Hedlund, and G Allan Johnson. “4-D micro-CT of the mouse heart.Mol Imaging 4, no. 2 (2005): 110–16. https://doi.org/10.1162/15353500200504187.
Badea CT, Fubara B, Hedlund LW, Johnson GA. 4-D micro-CT of the mouse heart. Mol Imaging. 2005;4(2):110–6.
Badea, Cristian T., et al. “4-D micro-CT of the mouse heart.Mol Imaging, vol. 4, no. 2, 2005, pp. 110–16. Pubmed, doi:10.1162/15353500200504187.
Badea CT, Fubara B, Hedlund LW, Johnson GA. 4-D micro-CT of the mouse heart. Mol Imaging. 2005;4(2):110–116.

Published In

Mol Imaging

DOI

ISSN

1535-3508

Publication Date

2005

Volume

4

Issue

2

Start / End Page

110 / 116

Location

England

Related Subject Headings

  • Tomography, X-Ray Computed
  • Nuclear Medicine & Medical Imaging
  • Mice, Inbred C57BL
  • Mice
  • Iopamidol
  • Iodine
  • Heart
  • Contrast Media
  • Animals
  • 4003 Biomedical engineering