Micro-CT with respiratory and cardiac gating.

Publication ,  Journal Article
Badea, C; Hedlund, LW; Johnson, GA
Published in: Med Phys
December 2004

Cardiopulmonary imaging in rodents using micro-computed tomography (CT) is a challenging task due to both cardiac and pulmonary motion and the limited fluence rate available from micro-focus x-ray tubes of most commercial systems. Successful imaging in the mouse requires recognition of both the spatial and temporal scales and their impact on the required fluence rate. Smaller voxels require an increase in the total number of photons (integrated fluence) used in the reconstructed image for constant signal-to-noise ratio. The faster heart rates require shorter exposures to minimize cardiac motion blur imposing even higher demands on the fluence rate. We describe a system with fixed tube/detector and with a rotating specimen. A large focal spot x-ray tube capable of producing high fluence rates with short exposure times was used. The geometry is optimized to match focal spot blur with detector pitch and the resolution limits imposed by the reproducibility of gating. Thus, it is possible to achieve isotropic spatial resolution of 100 microm with a fluence rate at the detector 250 times that of a conventional cone beam micro-CT system with rotating detector and microfocal x-ray tube. Motion is minimized for any single projection with 10 ms exposures that are synchronized to both cardiac and breathing motion. System performance was validated in vivo by studies of the cardiopulmonary structures in C57BL/6 mice, demonstrating the value of motion integration with a bright x-ray source.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

December 2004

Volume

31

Issue

12

Start / End Page

3324 / 3329

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Respiratory Mechanics
  • Radiographic Image Interpretation, Computer-Assisted
  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Movement
  • Mice, Inbred C57BL
  • Mice
  • Lung
  • Heart
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Badea, C., Hedlund, L. W., & Johnson, G. A. (2004). Micro-CT with respiratory and cardiac gating. Med Phys, 31(12), 3324–3329. https://doi.org/10.1118/1.1812604
Badea, C., L. W. Hedlund, and G. A. Johnson. “Micro-CT with respiratory and cardiac gating.Med Phys 31, no. 12 (December 2004): 3324–29. https://doi.org/10.1118/1.1812604.
Badea C, Hedlund LW, Johnson GA. Micro-CT with respiratory and cardiac gating. Med Phys. 2004 Dec;31(12):3324–9.
Badea, C., et al. “Micro-CT with respiratory and cardiac gating.Med Phys, vol. 31, no. 12, Dec. 2004, pp. 3324–29. Pubmed, doi:10.1118/1.1812604.
Badea C, Hedlund LW, Johnson GA. Micro-CT with respiratory and cardiac gating. Med Phys. 2004 Dec;31(12):3324–3329.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

December 2004

Volume

31

Issue

12

Start / End Page

3324 / 3329

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Respiratory Mechanics
  • Radiographic Image Interpretation, Computer-Assisted
  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Movement
  • Mice, Inbred C57BL
  • Mice
  • Lung
  • Heart