Skip to main content

A dual micro-CT system for small animal imaging.

Publication ,  Conference
Badea, CT; Johnston, S; Johnson, B; Lin, M; Hedlund, LW; Johnson, GA
Published in: Proc SPIE Int Soc Opt Eng
April 18, 2008

Micro-CT is a non-invasive imaging modality usually used to assess morphology in small animals. In our previous work, we have demonstrated that functional micro-CT imaging is also possible. This paper describes a dual micro-CT system with two fixed x-ray/detectors developed to address such challenging tasks as cardiac or perfusion studies in small animals. A two-tube/detector system ensures simultaneous acquisition of two projections, thus reducing scanning time and the number of contrast injections in perfusion studies by a factor of two. The system is integrated with software developed in-house for cardio-respiratory monitoring and gating. The sampling geometry was optimized for 88 microns in such a way that the geometric blur of the focal spot matches the Nyquist sample at the detector. A geometric calibration procedure allows one to combine projection data from the two chains into a single reconstructed volume. Image quality was measured in terms of spatial resolution, uniformity, noise, and linearity. The modulation transfer function (MTF) at 10% is 3.4 lp/mm for single detector reconstructions and 2.3 lp/mm for dual tube/detector reconstructions. We attribute this loss in spatial resolution to the compounding of slight errors in the separate single chain calibrations. The dual micro-CT system is currently used in studies for morphological and functional imaging of both rats and mice.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

April 18, 2008

Volume

6913

Start / End Page

691342

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Badea, C. T., Johnston, S., Johnson, B., Lin, M., Hedlund, L. W., & Johnson, G. A. (2008). A dual micro-CT system for small animal imaging. In Proc SPIE Int Soc Opt Eng (Vol. 6913, p. 691342). United States. https://doi.org/10.1117/12.772303
Badea, C. T., S. Johnston, B. Johnson, M. Lin, L. W. Hedlund, and G Allan Johnson. “A dual micro-CT system for small animal imaging.” In Proc SPIE Int Soc Opt Eng, 6913:691342, 2008. https://doi.org/10.1117/12.772303.
Badea CT, Johnston S, Johnson B, Lin M, Hedlund LW, Johnson GA. A dual micro-CT system for small animal imaging. In: Proc SPIE Int Soc Opt Eng. 2008. p. 691342.
Badea, C. T., et al. “A dual micro-CT system for small animal imaging.Proc SPIE Int Soc Opt Eng, vol. 6913, 2008, p. 691342. Pubmed, doi:10.1117/12.772303.
Badea CT, Johnston S, Johnson B, Lin M, Hedlund LW, Johnson GA. A dual micro-CT system for small animal imaging. Proc SPIE Int Soc Opt Eng. 2008. p. 691342.

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

April 18, 2008

Volume

6913

Start / End Page

691342

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering