Skip to main content

A dual micro-CT system for small animal imaging.

Publication ,  Conference
Badea, CT; Johnston, S; Johnson, B; Lin, M; Hedlund, LW; Johnson, GA
Published in: Proc SPIE Int Soc Opt Eng
April 18, 2008

Micro-CT is a non-invasive imaging modality usually used to assess morphology in small animals. In our previous work, we have demonstrated that functional micro-CT imaging is also possible. This paper describes a dual micro-CT system with two fixed x-ray/detectors developed to address such challenging tasks as cardiac or perfusion studies in small animals. A two-tube/detector system ensures simultaneous acquisition of two projections, thus reducing scanning time and the number of contrast injections in perfusion studies by a factor of two. The system is integrated with software developed in-house for cardio-respiratory monitoring and gating. The sampling geometry was optimized for 88 microns in such a way that the geometric blur of the focal spot matches the Nyquist sample at the detector. A geometric calibration procedure allows one to combine projection data from the two chains into a single reconstructed volume. Image quality was measured in terms of spatial resolution, uniformity, noise, and linearity. The modulation transfer function (MTF) at 10% is 3.4 lp/mm for single detector reconstructions and 2.3 lp/mm for dual tube/detector reconstructions. We attribute this loss in spatial resolution to the compounding of slight errors in the separate single chain calibrations. The dual micro-CT system is currently used in studies for morphological and functional imaging of both rats and mice.

Duke Scholars

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

April 18, 2008

Volume

6913

Start / End Page

691342

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Badea, C. T., Johnston, S., Johnson, B., Lin, M., Hedlund, L. W., & Johnson, G. A. (2008). A dual micro-CT system for small animal imaging. In Proc SPIE Int Soc Opt Eng (Vol. 6913, p. 691342). United States. https://doi.org/10.1117/12.772303
Badea, C. T., S. Johnston, B. Johnson, M. Lin, L. W. Hedlund, and G Allan Johnson. “A dual micro-CT system for small animal imaging.” In Proc SPIE Int Soc Opt Eng, 6913:691342, 2008. https://doi.org/10.1117/12.772303.
Badea CT, Johnston S, Johnson B, Lin M, Hedlund LW, Johnson GA. A dual micro-CT system for small animal imaging. In: Proc SPIE Int Soc Opt Eng. 2008. p. 691342.
Badea, C. T., et al. “A dual micro-CT system for small animal imaging.Proc SPIE Int Soc Opt Eng, vol. 6913, 2008, p. 691342. Pubmed, doi:10.1117/12.772303.
Badea CT, Johnston S, Johnson B, Lin M, Hedlund LW, Johnson GA. A dual micro-CT system for small animal imaging. Proc SPIE Int Soc Opt Eng. 2008. p. 691342.

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

April 18, 2008

Volume

6913

Start / End Page

691342

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering