Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions.

Publication ,  Journal Article
Liang, Z; Turkington, TG; Gilland, DR; Jaszczak, RJ; Coleman, RE
Published in: Phys Med Biol
March 1992

A three-dimensional reconstruction method for simultaneous compensation of attenuation, scatter and distance-dependent detector response for single photon emission computed tomography is described and tested by experimental studies. The method determines the attenuation factors recursively along each projection ray starting at the intersected source voxel closest to the detector. The method substracts the scatter energy window data from the primary energy window data for scatter compensation. The detector response is modelled to be spatially invariant at a constant distance from the detector. The method convolves source distribution with the modelled response function to compensate for the smoothed by use of a non-uniform entropy prior to searching for the maximum a posteriori probability solution. The method was tested using projections acquired from a chest phantom by a three-headed detector system with parallel hole collimators. An improvement was shown in image noise, recognition of object sizes and shapes, and quantification of concentration ratios.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Phys Med Biol

DOI

ISSN

0031-9155

Publication Date

March 1992

Volume

37

Issue

3

Start / End Page

587 / 603

Location

England

Related Subject Headings

  • Tomography, Emission-Computed, Single-Photon
  • Scattering, Radiation
  • Nuclear Medicine & Medical Imaging
  • Models, Structural
  • Image Processing, Computer-Assisted
  • 5105 Medical and biological physics
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Liang, Z., Turkington, T. G., Gilland, D. R., Jaszczak, R. J., & Coleman, R. E. (1992). Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions. Phys Med Biol, 37(3), 587–603. https://doi.org/10.1088/0031-9155/37/3/007
Liang, Z., T. G. Turkington, D. R. Gilland, R. J. Jaszczak, and R. E. Coleman. “Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions.Phys Med Biol 37, no. 3 (March 1992): 587–603. https://doi.org/10.1088/0031-9155/37/3/007.
Liang Z, Turkington TG, Gilland DR, Jaszczak RJ, Coleman RE. Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions. Phys Med Biol. 1992 Mar;37(3):587–603.
Liang, Z., et al. “Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions.Phys Med Biol, vol. 37, no. 3, Mar. 1992, pp. 587–603. Pubmed, doi:10.1088/0031-9155/37/3/007.
Liang Z, Turkington TG, Gilland DR, Jaszczak RJ, Coleman RE. Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions. Phys Med Biol. 1992 Mar;37(3):587–603.
Journal cover image

Published In

Phys Med Biol

DOI

ISSN

0031-9155

Publication Date

March 1992

Volume

37

Issue

3

Start / End Page

587 / 603

Location

England

Related Subject Headings

  • Tomography, Emission-Computed, Single-Photon
  • Scattering, Radiation
  • Nuclear Medicine & Medical Imaging
  • Models, Structural
  • Image Processing, Computer-Assisted
  • 5105 Medical and biological physics
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences