Serial measurements of CT attenuation and specific gravity in experimental cerebral edema.
Publication
, Journal Article
Rieth, KG; Fujiwara, K; Di Chiro, G; Klatzo, I; Brooks, RA; Johnston, GS; O'Connor, CM; Mitchell, LG
Published in: Radiology
May 1980
Vasogenic cerebral edema was induced cryogenically in rhesus monkeys. Serial scans in both axial and coronal planes were used to study the onset, peak, and regression of edema. Progression of edema, predominantly involving the white matter, was analyzed from the postmortem distribution of a blood/brain barrier indicator (Evans blue) injected at surgery. Specific gravity was measured in fresh, unfixed specimens from both the edematous and normal hemispheres and correlated with corresponding CT attenuation values obtained before death. The drop in specific gravity closely corresponded to the decrease in CT attenuation.
Duke Scholars
Published In
Radiology
DOI
ISSN
0033-8419
Publication Date
May 1980
Volume
135
Issue
2
Start / End Page
343 / 348
Location
United States
Related Subject Headings
- Tomography, X-Ray Computed
- Specific Gravity
- Nuclear Medicine & Medical Imaging
- Macaca mulatta
- Haplorhini
- Brain Edema
- Brain Chemistry
- Brain
- Animals
- 3202 Clinical sciences
Citation
APA
Chicago
ICMJE
MLA
NLM
Rieth, K. G., Fujiwara, K., Di Chiro, G., Klatzo, I., Brooks, R. A., Johnston, G. S., … Mitchell, L. G. (1980). Serial measurements of CT attenuation and specific gravity in experimental cerebral edema. Radiology, 135(2), 343–348. https://doi.org/10.1148/radiology.135.2.6768102
Rieth, K. G., K. Fujiwara, G. Di Chiro, I. Klatzo, R. A. Brooks, G. S. Johnston, C. M. O’Connor, and L. G. Mitchell. “Serial measurements of CT attenuation and specific gravity in experimental cerebral edema.” Radiology 135, no. 2 (May 1980): 343–48. https://doi.org/10.1148/radiology.135.2.6768102.
Rieth KG, Fujiwara K, Di Chiro G, Klatzo I, Brooks RA, Johnston GS, et al. Serial measurements of CT attenuation and specific gravity in experimental cerebral edema. Radiology. 1980 May;135(2):343–8.
Rieth, K. G., et al. “Serial measurements of CT attenuation and specific gravity in experimental cerebral edema.” Radiology, vol. 135, no. 2, May 1980, pp. 343–48. Pubmed, doi:10.1148/radiology.135.2.6768102.
Rieth KG, Fujiwara K, Di Chiro G, Klatzo I, Brooks RA, Johnston GS, O’Connor CM, Mitchell LG. Serial measurements of CT attenuation and specific gravity in experimental cerebral edema. Radiology. 1980 May;135(2):343–348.
Published In
Radiology
DOI
ISSN
0033-8419
Publication Date
May 1980
Volume
135
Issue
2
Start / End Page
343 / 348
Location
United States
Related Subject Headings
- Tomography, X-Ray Computed
- Specific Gravity
- Nuclear Medicine & Medical Imaging
- Macaca mulatta
- Haplorhini
- Brain Edema
- Brain Chemistry
- Brain
- Animals
- 3202 Clinical sciences