Skip to main content

Advancing optical imaging for breast margin assessment: an analysis of excisional time, cautery, and patent blue dye on underlying sources of contrast.

Publication ,  Journal Article
Bydlon, TM; Barry, WT; Kennedy, SA; Brown, JQ; Gallagher, JE; Wilke, LG; Geradts, J; Ramanujam, N
Published in: PLoS One
2012

Breast conserving surgery (BCS) is a recommended treatment for breast cancer patients where the goal is to remove the tumor and a surrounding rim of normal tissue. Unfortunately, a high percentage of patients return for additional surgeries to remove all of the cancer. Post-operative pathology is the gold standard for evaluating BCS margins but is limited due to the amount of tissue that can be sampled. Frozen section analysis and touch-preparation cytology have been proposed to address the surgical needs but also have sampling limitations. These issues represent an unmet clinical need for guidance in resecting malignant tissue intra-operatively and for pathological sampling. We have developed a quantitative spectral imaging device to examine margins intra-operatively. The context in which this technology is applied (intra-operative or post-operative setting) is influenced by time after excision and surgical factors including cautery and the presence of patent blue dye (specifically Lymphazurin™, used for sentinel lymph node mapping). Optical endpoints of hemoglobin ([THb]), fat ([β-carotene]), and fibroglandular content via light scattering (<µ(s)'>) measurements were quantified from diffuse reflectance spectra of lumpectomy and mastectomy specimens using a Monte Carlo model. A linear longitudinal mixed-effects model was used to fit the optical endpoints for the cautery and kinetics studies. Monte Carlo simulations and tissue mimicking phantoms were used for the patent blue dye experiments. [THb], [β-carotene], and <µ(s)'> were affected by <3.3% error with <80 µM of patent blue dye. The percent change in [β-carotene], <µ(s)'>, and [β-carotene]/<µ(s)'> was <14% in 30 minutes, while percent change in [THb] was >40%. [β-carotene] and [β-carotene]/<µ(s)'> were the only parameters not affected by cautery. This work demonstrates the importance of understanding the post-excision kinetics of ex-vivo tissue and the presence of cautery and patent blue dye for breast tumor margin assessment, to accurately interpret data and exploit underling sources of contrast.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

PLoS One

DOI

EISSN

1932-6203

Publication Date

2012

Volume

7

Issue

12

Start / End Page

e51418

Location

United States

Related Subject Headings

  • Rosaniline Dyes
  • Optical Imaging
  • Mastectomy, Segmental
  • Mastectomy
  • Humans
  • General Science & Technology
  • Female
  • Coloring Agents
  • Cautery
  • Breast Neoplasms
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Bydlon, T. M., Barry, W. T., Kennedy, S. A., Brown, J. Q., Gallagher, J. E., Wilke, L. G., … Ramanujam, N. (2012). Advancing optical imaging for breast margin assessment: an analysis of excisional time, cautery, and patent blue dye on underlying sources of contrast. PLoS One, 7(12), e51418. https://doi.org/10.1371/journal.pone.0051418
Bydlon, Torre M., William T. Barry, Stephanie A. Kennedy, J Quincy Brown, Jennifer E. Gallagher, Lee G. Wilke, Joseph Geradts, and Nimmi Ramanujam. “Advancing optical imaging for breast margin assessment: an analysis of excisional time, cautery, and patent blue dye on underlying sources of contrast.PLoS One 7, no. 12 (2012): e51418. https://doi.org/10.1371/journal.pone.0051418.
Bydlon TM, Barry WT, Kennedy SA, Brown JQ, Gallagher JE, Wilke LG, et al. Advancing optical imaging for breast margin assessment: an analysis of excisional time, cautery, and patent blue dye on underlying sources of contrast. PLoS One. 2012;7(12):e51418.
Bydlon, Torre M., et al. “Advancing optical imaging for breast margin assessment: an analysis of excisional time, cautery, and patent blue dye on underlying sources of contrast.PLoS One, vol. 7, no. 12, 2012, p. e51418. Pubmed, doi:10.1371/journal.pone.0051418.
Bydlon TM, Barry WT, Kennedy SA, Brown JQ, Gallagher JE, Wilke LG, Geradts J, Ramanujam N. Advancing optical imaging for breast margin assessment: an analysis of excisional time, cautery, and patent blue dye on underlying sources of contrast. PLoS One. 2012;7(12):e51418.

Published In

PLoS One

DOI

EISSN

1932-6203

Publication Date

2012

Volume

7

Issue

12

Start / End Page

e51418

Location

United States

Related Subject Headings

  • Rosaniline Dyes
  • Optical Imaging
  • Mastectomy, Segmental
  • Mastectomy
  • Humans
  • General Science & Technology
  • Female
  • Coloring Agents
  • Cautery
  • Breast Neoplasms