Transjugular intrahepatic portosystemic shunts (TIPS): effects of respiratory state and patient position on the measurement of Doppler velocities.

Publication ,  Journal Article
Kliewer, MA; Hertzberg, BS; Heneghan, JP; Suhocki, PV; Sheafor, DH; Gannon, PA; Paulson, EK
Published in: AJR Am J Roentgenol
July 2000

OBJECTIVE: The purpose of this prospective study was to examine the effects of patient position and respiratory state on the measurements of Doppler velocities in transjugular intrahepatic portosystemic shunts. SUBJECTS AND METHODS: Thirty-eight transjugular intrahepatic portosystemic shunts in 34 consecutive patients were studied using Doppler sonography. Peak velocities were measured in the mid shunt with the patient in three positions (supine, sitting upright, and left lateral decubitus) and two respiratory states (deep inspiration and quiet respiration). A mixed linear regression model was used to assess statistically significant differences among the six velocity measurements. RESULTS: Peak velocities in the mid stent averaged 22 cm/sec greater in quiet respiration than in deep inspiration, which was a significant difference (p < 0.00001). Differences in velocities in the three patient positions were not significant (p = 0.53). Using 90-190 cm/sec as the normal range, the peak velocity shifted from normal to abnormal levels by changing respiratory state in 17 (45%) of 38 studies. Using 60 cm/sec as the lower normal limit, the peak velocity fell below the normal range with inspiration in 10 (26%) of 38 studies. In 12 (32%) of 38 studies, a decline in peak velocity exceeding 50 cm/sec could be induced by inspiration. CONCLUSION: Peak systolic velocity in transjugular intrahepatic portosystemic shunts is substantially altered by the respiratory state of the patient at the time of the measurement, but not by the patient position. Respiratory state must be taken into account in the interpretation of peak velocity for shunt stenosis.

Duke Scholars

Published In

AJR Am J Roentgenol

DOI

ISSN

0361-803X

Publication Date

July 2000

Volume

175

Issue

1

Start / End Page

149 / 152

Location

United States

Related Subject Headings

  • Ultrasonography, Doppler
  • Respiration
  • Prospective Studies
  • Posture
  • Portasystemic Shunt, Transjugular Intrahepatic
  • Portal Vein
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kliewer, M. A., Hertzberg, B. S., Heneghan, J. P., Suhocki, P. V., Sheafor, D. H., Gannon, P. A., & Paulson, E. K. (2000). Transjugular intrahepatic portosystemic shunts (TIPS): effects of respiratory state and patient position on the measurement of Doppler velocities. AJR Am J Roentgenol, 175(1), 149–152. https://doi.org/10.2214/ajr.175.1.1750149
Kliewer, M. A., B. S. Hertzberg, J. P. Heneghan, P. V. Suhocki, D. H. Sheafor, P. A. Gannon, and E. K. Paulson. “Transjugular intrahepatic portosystemic shunts (TIPS): effects of respiratory state and patient position on the measurement of Doppler velocities.AJR Am J Roentgenol 175, no. 1 (July 2000): 149–52. https://doi.org/10.2214/ajr.175.1.1750149.
Kliewer MA, Hertzberg BS, Heneghan JP, Suhocki PV, Sheafor DH, Gannon PA, et al. Transjugular intrahepatic portosystemic shunts (TIPS): effects of respiratory state and patient position on the measurement of Doppler velocities. AJR Am J Roentgenol. 2000 Jul;175(1):149–52.
Kliewer, M. A., et al. “Transjugular intrahepatic portosystemic shunts (TIPS): effects of respiratory state and patient position on the measurement of Doppler velocities.AJR Am J Roentgenol, vol. 175, no. 1, July 2000, pp. 149–52. Pubmed, doi:10.2214/ajr.175.1.1750149.
Kliewer MA, Hertzberg BS, Heneghan JP, Suhocki PV, Sheafor DH, Gannon PA, Paulson EK. Transjugular intrahepatic portosystemic shunts (TIPS): effects of respiratory state and patient position on the measurement of Doppler velocities. AJR Am J Roentgenol. 2000 Jul;175(1):149–152.

Published In

AJR Am J Roentgenol

DOI

ISSN

0361-803X

Publication Date

July 2000

Volume

175

Issue

1

Start / End Page

149 / 152

Location

United States

Related Subject Headings

  • Ultrasonography, Doppler
  • Respiration
  • Prospective Studies
  • Posture
  • Portasystemic Shunt, Transjugular Intrahepatic
  • Portal Vein
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Humans