Skip to main content
Journal cover image

Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation.

Publication ,  Journal Article
Novak, MT; Yuan, F; Reichert, WM
Published in: Analytical and bioanalytical chemistry
October 2010

Little is known mechanistically about why implanted glucose sensors lag behind blood glucose levels in both the time to peak sensor response and the magnitude of peak sensor response. A mathematical model of glucose transport from capillaries through surrounding tissue to the sensor surface was constructed to address how different aspects of the tissue affect glucose transport to an implanted sensor. Physiologically relevant values of capsule diffusion coefficient, capsule porosity, cellular glucose consumption, capsule thickness, and subcutaneous vessel density were used as inputs to create simulated sensor traces that mimic experimental instances of time lag and concentration attenuation relative to a given blood glucose profile. Using logarithmic sensitivity analysis, each parameter was analyzed to study the effect of these variables on both lag and attenuation. Results identify capsule thickness as the strongest determinant of sensor time lag, while subcutaneous vessel density and capsule porosity had the largest effects on attenuation of glucose that reaches the sensor surface. These findings provide mechanistic insight for the rational design of sensor modifications that may alleviate the deleterious consequences of tissue effects on implanted sensor performance.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Analytical and bioanalytical chemistry

DOI

EISSN

1618-2650

ISSN

1618-2642

Publication Date

October 2010

Volume

398

Issue

4

Start / End Page

1695 / 1705

Related Subject Headings

  • Rats
  • Prostheses and Implants
  • Models, Biological
  • Microvessels
  • Kinetics
  • Glucose
  • Diffusion
  • Biosensing Techniques
  • Biological Transport
  • Animals
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Novak, M. T., Yuan, F., & Reichert, W. M. (2010). Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation. Analytical and Bioanalytical Chemistry, 398(4), 1695–1705. https://doi.org/10.1007/s00216-010-4097-6
Novak, Matthew T., Fan Yuan, and William M. Reichert. “Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation.Analytical and Bioanalytical Chemistry 398, no. 4 (October 2010): 1695–1705. https://doi.org/10.1007/s00216-010-4097-6.
Novak MT, Yuan F, Reichert WM. Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation. Analytical and bioanalytical chemistry. 2010 Oct;398(4):1695–705.
Novak, Matthew T., et al. “Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation.Analytical and Bioanalytical Chemistry, vol. 398, no. 4, Oct. 2010, pp. 1695–705. Epmc, doi:10.1007/s00216-010-4097-6.
Novak MT, Yuan F, Reichert WM. Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation. Analytical and bioanalytical chemistry. 2010 Oct;398(4):1695–1705.
Journal cover image

Published In

Analytical and bioanalytical chemistry

DOI

EISSN

1618-2650

ISSN

1618-2642

Publication Date

October 2010

Volume

398

Issue

4

Start / End Page

1695 / 1705

Related Subject Headings

  • Rats
  • Prostheses and Implants
  • Models, Biological
  • Microvessels
  • Kinetics
  • Glucose
  • Diffusion
  • Biosensing Techniques
  • Biological Transport
  • Animals