An efficient simulation tool is developed to generate realistic X-ray CT images, including a good modeling of physics and a very detailed anthropomorphic model in a reasonable computing time. This simulation tool consists in a coupling of the existing X-ray radiographic simulation software SINDBAD with the extended NURBS-Based Cardiac-Torso (XCAT) phantom. Both primary and scatter contributions in X-ray CT projections are calculated thanks to a combination of analytical and Monte Carlo approaches. The representation of the XCAT phantom is adapted to the level of resolution required by the primary and scatter images. We present in this paper first X-ray CT projection data which are simulated under an angiography configuration. Although the XCAT phantom is complex, the computation time is reasonable, even with the estimation of the scatter radiation. In future studies, similar simulations will be performed in real clinical CT scanner conditions, with an accurate modelling of detectors and a finer representation of the XCAT phantom, and will be compared with real X-rays CT images for validation. ©2009 IEEE.

Duke Scholars

Published In

IEEE Nuclear Science Symposium Conference Record

DOI

ISSN

1095-7863

Publication Date

December 1, 2009

Start / End Page

3980 / 3983
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tabary, J., Marache-Francisco, S., Valette, S., Segars, W. P., & Lartizien, C. (2009). Realistic X-ray CT simulation of the XCAT phantom with SINDBAD. IEEE Nuclear Science Symposium Conference Record, 3980–3983. https://doi.org/10.1109/NSSMIC.2009.5401942
Tabary, J., S. Marache-Francisco, S. Valette, W. P. Segars, and C. Lartizien. “Realistic X-ray CT simulation of the XCAT phantom with SINDBAD.” IEEE Nuclear Science Symposium Conference Record, December 1, 2009, 3980–83. https://doi.org/10.1109/NSSMIC.2009.5401942.
Tabary J, Marache-Francisco S, Valette S, Segars WP, Lartizien C. Realistic X-ray CT simulation of the XCAT phantom with SINDBAD. IEEE Nuclear Science Symposium Conference Record. 2009 Dec 1;3980–3.
Tabary, J., et al. “Realistic X-ray CT simulation of the XCAT phantom with SINDBAD.” IEEE Nuclear Science Symposium Conference Record, Dec. 2009, pp. 3980–83. Scopus, doi:10.1109/NSSMIC.2009.5401942.
Tabary J, Marache-Francisco S, Valette S, Segars WP, Lartizien C. Realistic X-ray CT simulation of the XCAT phantom with SINDBAD. IEEE Nuclear Science Symposium Conference Record. 2009 Dec 1;3980–3983.

Published In

IEEE Nuclear Science Symposium Conference Record

DOI

ISSN

1095-7863

Publication Date

December 1, 2009

Start / End Page

3980 / 3983