Skip to main content
Journal cover image

In vitro monitoring of the dynamic elasticity changes during radiofrequency ablation with acoustic radiation force impulse imaging.

Publication ,  Journal Article
Eyerly, SA; Dumont, DM; Trahey, GE; Wolf, PD
Published in: Journal of cardiovascular electrophysiology
April 2013

Duke Scholars

Published In

Journal of cardiovascular electrophysiology

DOI

EISSN

1540-8167

ISSN

1045-3873

Publication Date

April 2013

Volume

24

Issue

4

Start / End Page

472 / 473

Related Subject Headings

  • Time Factors
  • Swine
  • Myocardium
  • Elasticity Imaging Techniques
  • Elasticity
  • Catheter Ablation
  • Cardiovascular System & Hematology
  • Animals
  • 3201 Cardiovascular medicine and haematology
  • 1102 Cardiorespiratory Medicine and Haematology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Eyerly, S. A., Dumont, D. M., Trahey, G. E., & Wolf, P. D. (2013). In vitro monitoring of the dynamic elasticity changes during radiofrequency ablation with acoustic radiation force impulse imaging. Journal of Cardiovascular Electrophysiology, 24(4), 472–473. https://doi.org/10.1111/jce.12008
Eyerly, Stephanie A., Douglas M. Dumont, Gregg E. Trahey, and Patrick D. Wolf. “In vitro monitoring of the dynamic elasticity changes during radiofrequency ablation with acoustic radiation force impulse imaging.Journal of Cardiovascular Electrophysiology 24, no. 4 (April 2013): 472–73. https://doi.org/10.1111/jce.12008.
Eyerly SA, Dumont DM, Trahey GE, Wolf PD. In vitro monitoring of the dynamic elasticity changes during radiofrequency ablation with acoustic radiation force impulse imaging. Journal of cardiovascular electrophysiology. 2013 Apr;24(4):472–3.
Eyerly, Stephanie A., et al. “In vitro monitoring of the dynamic elasticity changes during radiofrequency ablation with acoustic radiation force impulse imaging.Journal of Cardiovascular Electrophysiology, vol. 24, no. 4, Apr. 2013, pp. 472–73. Epmc, doi:10.1111/jce.12008.
Eyerly SA, Dumont DM, Trahey GE, Wolf PD. In vitro monitoring of the dynamic elasticity changes during radiofrequency ablation with acoustic radiation force impulse imaging. Journal of cardiovascular electrophysiology. 2013 Apr;24(4):472–473.
Journal cover image

Published In

Journal of cardiovascular electrophysiology

DOI

EISSN

1540-8167

ISSN

1045-3873

Publication Date

April 2013

Volume

24

Issue

4

Start / End Page

472 / 473

Related Subject Headings

  • Time Factors
  • Swine
  • Myocardium
  • Elasticity Imaging Techniques
  • Elasticity
  • Catheter Ablation
  • Cardiovascular System & Hematology
  • Animals
  • 3201 Cardiovascular medicine and haematology
  • 1102 Cardiorespiratory Medicine and Haematology