Comparison of transmission acquisition approaches for SPECT nonuniform attenuation compensation

Publication ,  Journal Article
Gilland, DR; Jaszczak, RJ; Turkington, TG; Coleman, RE
Published in: IEEE Nuclear Science Symposium & Medical Imaging Conference
December 1, 1997

This study compared two approaches for acquiring transmission computed tomography (TCT) data for SPECT nonuniform attenuation compensation. One approach, which has been implemented in commercial SPECT systems, acquires the TCT and SPECT data simultaneously using a scanning transmission line source, dual head SPECT system and parallel beam collimation (PB-sim). The other approach acquires the TCT and SPECT data sequentially using long focus, off-set fan beam collimation with a non-scanning line source and a triple head system (FB-seq). The two systems were compared based on (a) the noise level of the TCT data, (b) the spatial resolution of the TCT data, and (c) the quality of reconstructed TCT and SPECT images of a thorax phantom. For the thorax phantom data, a fast TCT scan was used (2 min.) and total scan time (TCT and SPECT) was the same for the two systems. The results from the TCT noise measurements showed that for the source activities used here (400 mCi for PB-sim, 56 mCi for FB-seq), PB-sim had higher count density in the lung region whereas FB-seq had higher in the heart and liver regions. The measured TCT spatial resolution for the two systems was comparable in the axial direction but far superior with FB-seq in the transaxial direction. This difference in resolution was apparent in the reconstructed TCT images. The SPECT images from the two systems demonstrated the effects of attenuation compensation.

Duke Scholars

Published In

IEEE Nuclear Science Symposium & Medical Imaging Conference

Publication Date

December 1, 1997

Volume

2

Start / End Page

1556 / 1560
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Gilland, D. R., Jaszczak, R. J., Turkington, T. G., & Coleman, R. E. (1997). Comparison of transmission acquisition approaches for SPECT nonuniform attenuation compensation. IEEE Nuclear Science Symposium & Medical Imaging Conference, 2, 1556–1560.
Gilland, D. R., R. J. Jaszczak, T. G. Turkington, and R. E. Coleman. “Comparison of transmission acquisition approaches for SPECT nonuniform attenuation compensation.” IEEE Nuclear Science Symposium & Medical Imaging Conference 2 (December 1, 1997): 1556–60.
Gilland DR, Jaszczak RJ, Turkington TG, Coleman RE. Comparison of transmission acquisition approaches for SPECT nonuniform attenuation compensation. IEEE Nuclear Science Symposium & Medical Imaging Conference. 1997 Dec 1;2:1556–60.
Gilland, D. R., et al. “Comparison of transmission acquisition approaches for SPECT nonuniform attenuation compensation.” IEEE Nuclear Science Symposium & Medical Imaging Conference, vol. 2, Dec. 1997, pp. 1556–60.
Gilland DR, Jaszczak RJ, Turkington TG, Coleman RE. Comparison of transmission acquisition approaches for SPECT nonuniform attenuation compensation. IEEE Nuclear Science Symposium & Medical Imaging Conference. 1997 Dec 1;2:1556–1560.

Published In

IEEE Nuclear Science Symposium & Medical Imaging Conference

Publication Date

December 1, 1997

Volume

2

Start / End Page

1556 / 1560