Skip to main content
Journal cover image

Endoscopic removal of metallic airway stents.

Publication ,  Journal Article
Lunn, W; Feller-Kopman, D; Wahidi, M; Ashiku, S; Thurer, R; Ernst, A
Published in: Chest
June 2005

BACKGROUND: Complications of metallic airway stents include granulation tissue formation, fracture of struts, migration, and mucous plugging. When these complications result in airway injury or obstruction, it may become necessary to remove the stent. There have been few reports detailing techniques and complications associated with endoscopic removal of metallic airway stents. We report our experience with endoscopic removal of 30 such stents over a 3-year period. METHODS: We conducted a retrospective review of 25 patients who underwent endoscopic stent removal from March 2001 to April 2004. The patients ranged in age from 17 to 80 years (mean, 56.3 years). There were 10 male and 15 female patients. The stents had been placed for nonmalignant disease in 20 patients (80%) and malignant disease in 5 patients (20%). All procedures were done under general anesthesia with a rigid bronchoscope. Special attention was focused on the technique of stent removal and postoperative complications. RESULTS: Thirty metallic airway stents were successfully removed from 25 consecutive patients over a 3-year period. The basic method of removal involved the steady application of traction to the stent with alligator forceps. In all cases, an instrument such as the barrel of the rigid bronchoscope or a Jackson dilator was employed to help separate the stent from the airway wall before removal was attempted. In some instances, the airway wall was pretreated with thermal energy prior to stent removal. Complications were as follows: retained stent pieces (n = 7), mucosal tear with bleeding (n = 4), re-obstruction requiring temporary silicone stent placement (n = 14), need for postoperative mechanical ventilation (n = 6), and tension pneumothorax (n = 1). CONCLUSIONS: Although metallic stents may be safely removed endoscopically, complications are common and must be anticipated. Other investigators have described airway obstruction and death as a result of attempted stent removal. Placement and removal of metallic airway stents should only be performed at centers that are prepared to deal with the potentially life-threatening complications.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Chest

DOI

ISSN

0012-3692

Publication Date

June 2005

Volume

127

Issue

6

Start / End Page

2106 / 2112

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Survival Rate
  • Stents
  • Risk Assessment
  • Respiratory System
  • Middle Aged
  • Metals
  • Male
  • Humans
  • Foreign-Body Migration
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lunn, W., Feller-Kopman, D., Wahidi, M., Ashiku, S., Thurer, R., & Ernst, A. (2005). Endoscopic removal of metallic airway stents. Chest, 127(6), 2106–2112. https://doi.org/10.1378/chest.127.6.2106
Lunn, William, David Feller-Kopman, Momen Wahidi, Simon Ashiku, Robert Thurer, and Armin Ernst. “Endoscopic removal of metallic airway stents.Chest 127, no. 6 (June 2005): 2106–12. https://doi.org/10.1378/chest.127.6.2106.
Lunn W, Feller-Kopman D, Wahidi M, Ashiku S, Thurer R, Ernst A. Endoscopic removal of metallic airway stents. Chest. 2005 Jun;127(6):2106–12.
Lunn, William, et al. “Endoscopic removal of metallic airway stents.Chest, vol. 127, no. 6, June 2005, pp. 2106–12. Pubmed, doi:10.1378/chest.127.6.2106.
Lunn W, Feller-Kopman D, Wahidi M, Ashiku S, Thurer R, Ernst A. Endoscopic removal of metallic airway stents. Chest. 2005 Jun;127(6):2106–2112.
Journal cover image

Published In

Chest

DOI

ISSN

0012-3692

Publication Date

June 2005

Volume

127

Issue

6

Start / End Page

2106 / 2112

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Survival Rate
  • Stents
  • Risk Assessment
  • Respiratory System
  • Middle Aged
  • Metals
  • Male
  • Humans
  • Foreign-Body Migration