Accurate temperature imaging based on intermolecular coherences in magnetic resonance.
Publication
, Journal Article
Galiana, G; Branca, RT; Jenista, ER; Warren, WS
Published in: Science (New York, N.Y.)
October 2008
Conventional magnetic resonance methods that provide interior temperature profiles, which find use in clinical applications such as hyperthermic therapy, can develop inaccuracies caused by the inherently inhomogeneous magnetic field within tissues or by probe dynamics, and work poorly in important applications such as fatty tissues. We present a magnetic resonance method that is suitable for imaging temperature in a wide range of environments. It uses the inherently sharp resonances of intermolecular zero-quantum coherences, in this case flipping up a water spin while flipping down a nearby fat spin. We show that this method can rapidly and accurately assign temperatures in vivo on an absolute scale.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
Science (New York, N.Y.)
DOI
EISSN
1095-9203
ISSN
0036-8075
Publication Date
October 2008
Volume
322
Issue
5900
Start / End Page
421 / 424
Related Subject Headings
- Water
- Temperature
- Mice, Obese
- Mice
- Magnetic Resonance Imaging
- Lipids
- General Science & Technology
- Body Temperature
- Animals
Citation
APA
Chicago
ICMJE
MLA
NLM
Galiana, G., Branca, R. T., Jenista, E. R., & Warren, W. S. (2008). Accurate temperature imaging based on intermolecular coherences in magnetic resonance. Science (New York, N.Y.), 322(5900), 421–424. https://doi.org/10.1126/science.1163242
Galiana, Gigi, Rosa T. Branca, Elizabeth R. Jenista, and Warren S. Warren. “Accurate temperature imaging based on intermolecular coherences in magnetic resonance.” Science (New York, N.Y.) 322, no. 5900 (October 2008): 421–24. https://doi.org/10.1126/science.1163242.
Galiana G, Branca RT, Jenista ER, Warren WS. Accurate temperature imaging based on intermolecular coherences in magnetic resonance. Science (New York, NY). 2008 Oct;322(5900):421–4.
Galiana, Gigi, et al. “Accurate temperature imaging based on intermolecular coherences in magnetic resonance.” Science (New York, N.Y.), vol. 322, no. 5900, Oct. 2008, pp. 421–24. Epmc, doi:10.1126/science.1163242.
Galiana G, Branca RT, Jenista ER, Warren WS. Accurate temperature imaging based on intermolecular coherences in magnetic resonance. Science (New York, NY). 2008 Oct;322(5900):421–424.
Published In
Science (New York, N.Y.)
DOI
EISSN
1095-9203
ISSN
0036-8075
Publication Date
October 2008
Volume
322
Issue
5900
Start / End Page
421 / 424
Related Subject Headings
- Water
- Temperature
- Mice, Obese
- Mice
- Magnetic Resonance Imaging
- Lipids
- General Science & Technology
- Body Temperature
- Animals