The probability of defibrillation success and the incidence of postshock arrhythmia as a function of shock strength.

Publication ,  Journal Article
Cates, AW; Wolf, PD; Hillsley, RE; Souza, JJ; Smith, WM; Ideker, RE
Published in: Pacing and clinical electrophysiology : PACE
July 1994

The effects of high voltage defibrillation shocks given to six swine were studied to determine if there is a limit to the advantage gained from increasing the shock strength. An endocardial electrode was placed in the right ventricle, and a 114-cm2 cutaneous patch was placed on the left lateral thorax. Monophasic (10 msec) and single capacitor biphasic (5/5 msec) shocks with leading edge voltages of 200, 400, 600, 800, and 990 volts (approximately 2.3-59 J) were tested. For monophasic shocks, the probability of successful defibrillation ranged from 0% at 200 V to 90% at 990 V. The incidence of postshock arrhythmia increased from 0% for successful shocks at 600 V to 67% for successful shocks at 990 V. For biphasic shocks, the probability of success peaked at 97% for the 600-, 800-, and 990-V shocks. The incidence of postshock arrhythmia increased from 8% at 400 V to 55% at 990 V. Although more postshock arrhythmias occurred at lower strengths for biphasic than for monophasic shocks, an efficacy criterion, quantifying the probability of defibrillation success and the probability that a postshock arrhythmia will not occur, was always higher for biphasic shocks. The probability of success never reached 100% for either waveform while the incidence of postshock arrhythmia increased as the shock strength increased. In conclusion, for the catheter-patch electrode configuration, increasing the shock strength does not always improve the probability of success and may increase the incidence of postshock arrhythmia.

Duke Scholars

Published In

Pacing and clinical electrophysiology : PACE

DOI

EISSN

1540-8159

ISSN

0147-8389

Publication Date

July 1994

Volume

17

Issue

7

Start / End Page

1208 / 1217

Related Subject Headings

  • Treatment Outcome
  • Tachycardia
  • Swine
  • Probability
  • Incidence
  • Electrodes
  • Electrocardiography
  • Electricity
  • Electric Countershock
  • Defibrillators, Implantable
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cates, A. W., Wolf, P. D., Hillsley, R. E., Souza, J. J., Smith, W. M., & Ideker, R. E. (1994). The probability of defibrillation success and the incidence of postshock arrhythmia as a function of shock strength. Pacing and Clinical Electrophysiology : PACE, 17(7), 1208–1217. https://doi.org/10.1111/j.1540-8159.1994.tb01487.x
Cates, A. W., P. D. Wolf, R. E. Hillsley, J. J. Souza, W. M. Smith, and R. E. Ideker. “The probability of defibrillation success and the incidence of postshock arrhythmia as a function of shock strength.Pacing and Clinical Electrophysiology : PACE 17, no. 7 (July 1994): 1208–17. https://doi.org/10.1111/j.1540-8159.1994.tb01487.x.
Cates AW, Wolf PD, Hillsley RE, Souza JJ, Smith WM, Ideker RE. The probability of defibrillation success and the incidence of postshock arrhythmia as a function of shock strength. Pacing and clinical electrophysiology : PACE. 1994 Jul;17(7):1208–17.
Cates, A. W., et al. “The probability of defibrillation success and the incidence of postshock arrhythmia as a function of shock strength.Pacing and Clinical Electrophysiology : PACE, vol. 17, no. 7, July 1994, pp. 1208–17. Epmc, doi:10.1111/j.1540-8159.1994.tb01487.x.
Cates AW, Wolf PD, Hillsley RE, Souza JJ, Smith WM, Ideker RE. The probability of defibrillation success and the incidence of postshock arrhythmia as a function of shock strength. Pacing and clinical electrophysiology : PACE. 1994 Jul;17(7):1208–1217.

Published In

Pacing and clinical electrophysiology : PACE

DOI

EISSN

1540-8159

ISSN

0147-8389

Publication Date

July 1994

Volume

17

Issue

7

Start / End Page

1208 / 1217

Related Subject Headings

  • Treatment Outcome
  • Tachycardia
  • Swine
  • Probability
  • Incidence
  • Electrodes
  • Electrocardiography
  • Electricity
  • Electric Countershock
  • Defibrillators, Implantable