Skip to main content

Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation.

Publication ,  Journal Article
Wharton, JM; Wolf, PD; Smith, WM; Chen, PS; Frazier, DW; Yabe, S; Danieley, N; Ideker, RE
Published in: Circulation
April 1992

Potential gradient field determination may be a helpful means of describing the effects of defibrillation shocks; however, potential gradient field requirements for defibrillation with different electrode configurations have not been established.To evaluate the field requirements for defibrillation, potential fields during defibrillation shocks and the following ventricular activations were recorded with 74 epicardial electrodes in 12 open-chest dogs with the use of a computerized mapping system. Shock electrodes (2.64 cm2) were attached to the lateral right atrium (R), lateral left ventricular base (L), and left ventricular apex (V). Four electrode configurations were tested: single shocks of 14-msec duration given to two single anode-single cathode configurations, R:V and L:V, and to one dual anode-single cathode configuration, (R+L):V; and sequential 7-msec shocks separated by 1 msec given to R:V and L:V (R:V----L:V). Defibrillation threshold (DFT) current was significantly lower for R:V----L:V than for the other configurations and markedly higher for L:V. Despite these differences, the minimum potential gradients measured at DFT were not significantly different (approximately 6-7 V/cm for each electrode configuration). Potential gradient fields generated by the electrode configurations were markedly uneven, with a 15-27-fold change from lowest to highest gradient, with the greatest decrease in gradient occurring near the shock electrodes. Although gradient fields varied with the electrode configuration, all configurations produced weak fields along the right ventricular base. Early sites of epicardial activation after all unsuccessful shocks occurred in areas in which the field was weak; 87% occurred at sites with gradients less than 15 V/cm. Ventricular tachycardia originating in high gradient areas near shock electrodes followed 11 of 67 successful shocks.These data suggest that 1) defibrillation fields created by small epicardial electrodes are very uneven; 2) achievement of a certain minimum potential gradient over both ventricles is necessary for ventricular defibrillation; 3) the difference in shock strengths required to achieve this minimum gradient over both ventricles may explain the differences in DFTs for various electrode configurations; and 4) high gradient areas in the uneven fields can induce ectopic activation after successful shocks.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Circulation

DOI

EISSN

1524-4539

ISSN

0009-7322

Publication Date

April 1992

Volume

85

Issue

4

Start / End Page

1510 / 1523

Related Subject Headings

  • Pericardium
  • Heart Conduction System
  • Electrodes, Implanted
  • Electrocardiography
  • Electric Countershock
  • Electric Conductivity
  • Dogs
  • Cardiovascular System & Hematology
  • Cardiac Pacing, Artificial
  • Animals
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wharton, J. M., Wolf, P. D., Smith, W. M., Chen, P. S., Frazier, D. W., Yabe, S., … Ideker, R. E. (1992). Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation. Circulation, 85(4), 1510–1523. https://doi.org/10.1161/01.cir.85.4.1510
Wharton, J. M., P. D. Wolf, W. M. Smith, P. S. Chen, D. W. Frazier, S. Yabe, N. Danieley, and R. E. Ideker. “Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation.Circulation 85, no. 4 (April 1992): 1510–23. https://doi.org/10.1161/01.cir.85.4.1510.
Wharton JM, Wolf PD, Smith WM, Chen PS, Frazier DW, Yabe S, et al. Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation. Circulation. 1992 Apr;85(4):1510–23.
Wharton, J. M., et al. “Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation.Circulation, vol. 85, no. 4, Apr. 1992, pp. 1510–23. Epmc, doi:10.1161/01.cir.85.4.1510.
Wharton JM, Wolf PD, Smith WM, Chen PS, Frazier DW, Yabe S, Danieley N, Ideker RE. Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation. Circulation. 1992 Apr;85(4):1510–1523.

Published In

Circulation

DOI

EISSN

1524-4539

ISSN

0009-7322

Publication Date

April 1992

Volume

85

Issue

4

Start / End Page

1510 / 1523

Related Subject Headings

  • Pericardium
  • Heart Conduction System
  • Electrodes, Implanted
  • Electrocardiography
  • Electric Countershock
  • Electric Conductivity
  • Dogs
  • Cardiovascular System & Hematology
  • Cardiac Pacing, Artificial
  • Animals