Skip to main content

CT colonography: investigation of the optimum reader paradigm by using computer-aided detection software.

Publication ,  Conference
Taylor, SA; Charman, SC; Lefere, P; McFarland, EG; Paulson, EK; Yee, J; Aslam, R; Barlow, JM; Gupta, A; Kim, DH; Miller, CM; Halligan, S
Published in: Radiology
February 2008

PURPOSE: To prospectively compare the diagnostic performance and time efficiency of both second and concurrent computer-aided detection (CAD) reading paradigms for retrospectively obtained computed tomographic (CT) colonography data sets by using consensus reading (three radiologists) of colonoscopic findings as a reference standard. MATERIALS AND METHODS: Ethical permission, HIPAA compliance (for U.S. institutions), and patient consent were obtained from all institutions for use of CT colonography data sets in this study. Ten radiologists each read 25 CT colonography data sets (12 men, 13 women; mean age, 61 years) containing 69 polyps (28 were 1-5 mm, 41 were >or=6 mm) by using workstations integrated with CAD software. Reading was randomized to either "second read" CAD (applied only after initial unassisted assessment) or "concurrent read" CAD (applied at the start of assessment). Data sets were reread 6 weeks later by using the opposing paradigm. Polyp sensitivity and reading times were compared by using multilevel logistic and linear regression, respectively. Receiver operating characteristic (ROC) curves were generated. RESULTS: Compared with the unassisted read, odds of improved polyp (>or=6 mm) detection were 1.5 (95% confidence interval [CI]: 1.0, 2.2) and 1.3 (95% CI: 0.9, 1.9) by using CAD as second and concurrent reader, respectively. Detection odds by using CAD concurrently were 0.87 (95% CI: 0.59, 1.3) and 0.76 (95% CI: 0.57, 1.01) those of second read CAD, excluding and including polyps 1-5 mm, respectively. The concurrent read took 2.9 minutes (95% CI: -3.8, -1.9) less than did second read. The mean areas under the ROC curve (95% CI) for the unassisted read, second read CAD, and concurrent read CAD were 0.83 (95% CI: 0.78, 0.87), 0.86 (95% CI: 0.82, 0.90), and 0.88 (95% CI: 0.83, 0.92), respectively. CONCLUSION: CAD is more time efficient when used concurrently than when used as a second reader, with similar sensitivity for polyps 6 mm or larger. However, use of second read CAD maximizes sensitivity, particularly for smaller lesions.

Duke Scholars

Published In

Radiology

DOI

EISSN

1527-1315

Publication Date

February 2008

Volume

246

Issue

2

Start / End Page

463 / 471

Location

United States

Related Subject Headings

  • Software
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Pattern Recognition, Automated
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Taylor, S. A., Charman, S. C., Lefere, P., McFarland, E. G., Paulson, E. K., Yee, J., … Halligan, S. (2008). CT colonography: investigation of the optimum reader paradigm by using computer-aided detection software. In Radiology (Vol. 246, pp. 463–471). United States. https://doi.org/10.1148/radiol.2461070190
Taylor, Stuart A., Susan C. Charman, Philippe Lefere, Elizabeth G. McFarland, Erik K. Paulson, Judy Yee, Rizwan Aslam, et al. “CT colonography: investigation of the optimum reader paradigm by using computer-aided detection software.” In Radiology, 246:463–71, 2008. https://doi.org/10.1148/radiol.2461070190.
Taylor SA, Charman SC, Lefere P, McFarland EG, Paulson EK, Yee J, et al. CT colonography: investigation of the optimum reader paradigm by using computer-aided detection software. In: Radiology. 2008. p. 463–71.
Taylor, Stuart A., et al. “CT colonography: investigation of the optimum reader paradigm by using computer-aided detection software.Radiology, vol. 246, no. 2, 2008, pp. 463–71. Pubmed, doi:10.1148/radiol.2461070190.
Taylor SA, Charman SC, Lefere P, McFarland EG, Paulson EK, Yee J, Aslam R, Barlow JM, Gupta A, Kim DH, Miller CM, Halligan S. CT colonography: investigation of the optimum reader paradigm by using computer-aided detection software. Radiology. 2008. p. 463–471.

Published In

Radiology

DOI

EISSN

1527-1315

Publication Date

February 2008

Volume

246

Issue

2

Start / End Page

463 / 471

Location

United States

Related Subject Headings

  • Software
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Pattern Recognition, Automated
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Image Interpretation, Computer-Assisted
  • Image Enhancement