Skip to main content

Wireless headstage for neural prosthetics

Publication ,  Conference
Morizio, J; Irazoqui, P; Go, V; Parmentier, J
Published in: 2nd International IEEE EMBS Conference on Neural Engineering
December 1, 2005

The continuous monitoring of electrical brain activity with implanted electrodes is essential for understanding the neural substrates of many physiological and pathological brain functions. Although this is done in some patients before undergoing surgical treatment, such recordings are extremely difficult in experimental animals, particularly in small rodents. The wires from the implanted electrodes restrain and interfere with the natural behavior of the animals. Consequently, it has been impossible to correlate truly normal behavior with neuronal activity. In addition, it would be ideal if brain activity could be monitored while animals live in a natural and enriched environment. A neural prosthetic device is comprised of a hardware system that records neural activity from the brain and then decodes it into control signals that in turn can be used to move robotic devices or muscles. Today's neural prosthetic devices typically use tethered headstage connections [1] that interface the brain headstage electronics to the remote spike sorting processors located at the controlled devices. In this paper we present the circuits, layouts and test data for a multi-channel wireless headstage system which includes the headstage transmitter and receiver components. © 2005 IEEE.

Duke Scholars

Published In

2nd International IEEE EMBS Conference on Neural Engineering

DOI

Publication Date

December 1, 2005

Volume

2005

Start / End Page

414 / 417
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Morizio, J., Irazoqui, P., Go, V., & Parmentier, J. (2005). Wireless headstage for neural prosthetics. In 2nd International IEEE EMBS Conference on Neural Engineering (Vol. 2005, pp. 414–417). https://doi.org/10.1109/CNE.2005.1419647
Morizio, J., P. Irazoqui, V. Go, and J. Parmentier. “Wireless headstage for neural prosthetics.” In 2nd International IEEE EMBS Conference on Neural Engineering, 2005:414–17, 2005. https://doi.org/10.1109/CNE.2005.1419647.
Morizio J, Irazoqui P, Go V, Parmentier J. Wireless headstage for neural prosthetics. In: 2nd International IEEE EMBS Conference on Neural Engineering. 2005. p. 414–7.
Morizio, J., et al. “Wireless headstage for neural prosthetics.” 2nd International IEEE EMBS Conference on Neural Engineering, vol. 2005, 2005, pp. 414–17. Scopus, doi:10.1109/CNE.2005.1419647.
Morizio J, Irazoqui P, Go V, Parmentier J. Wireless headstage for neural prosthetics. 2nd International IEEE EMBS Conference on Neural Engineering. 2005. p. 414–417.

Published In

2nd International IEEE EMBS Conference on Neural Engineering

DOI

Publication Date

December 1, 2005

Volume

2005

Start / End Page

414 / 417