Organ dose in chest CT: Effect of modulation scheme on estimation accuracy

Publication ,  Journal Article
Li, X; Segars, WP; Samei, E
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
June 3, 2013

The purpose of this study was to evaluate how different implementations of the tube current modulation (TCM) technology affect organ dose conversion factors in chest CT and how organ dose can be accurately estimated for various modulation schemes. Computational phantom of a normal-weight female patient was used. A method was developed to generate tube current (mA) modulation profiles based on the attenuation of the phantom, taking into account the geometry of the CT system as well as the x-ray energy spectrum and bowtie filtration in a CT scan. The mA for a given projection angle was calculated as a power-law function of the attenuation along this projection. The exponent of this function, termed modulation control strength, was varied from 0 to 1 to emulate the effects of different TCM schemes. Organ dose was estimated for a chest scan for each modulation scheme and was subsequently normalized by volume-weighted CT dose index (CTDIvol) to obtain conversion factors. The results showed that the conversion factors are second-order polynomial functions of the modulation control strength. The conversion factors established for a fixed-mA scan may be used to estimate organ dose in a TCM scan. For organs on the periphery of the scan coverage, the best accuracy is achieved when using CTDIvol computed from the average mA of the entire scan. For organs inside the scan coverage, the best accuracy is achieved when using CTDIvol computed from the volume-averaged mA values of all the axial slices containing the organ. © 2013 SPIE.

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 3, 2013

Volume

8668
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Li, X., Segars, W. P., & Samei, E. (2013). Organ dose in chest CT: Effect of modulation scheme on estimation accuracy. Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 8668. https://doi.org/10.1117/12.2008505
Li, X., W. P. Segars, and E. Samei. “Organ dose in chest CT: Effect of modulation scheme on estimation accuracy.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE 8668 (June 3, 2013). https://doi.org/10.1117/12.2008505.
Li X, Segars WP, Samei E. Organ dose in chest CT: Effect of modulation scheme on estimation accuracy. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2013 Jun 3;8668.
Li, X., et al. “Organ dose in chest CT: Effect of modulation scheme on estimation accuracy.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 8668, June 2013. Scopus, doi:10.1117/12.2008505.
Li X, Segars WP, Samei E. Organ dose in chest CT: Effect of modulation scheme on estimation accuracy. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2013 Jun 3;8668.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 3, 2013

Volume

8668