How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator?
Conferences
Oldham, M; Newton, J; Rankine, L; Adamovics, J; Kirsch, D; Das, S
Published in: J Phys Conf Ser
2013
There is significant interest in delivering precisely targeted small-volume radiation treatments, in the pre-clinical setting, to study dose-volume relationships with tumor control and normal tissue damage. In this work we investigate the IGRT targeting accuracy of the XRad225Cx system from Precision x-Ray using high resolution 3D dosimetry techniques. Initial results revealed a significant targeting error of about 2.4mm. This error was reduced to within 0.5mm after the IGRT hardware and software had been recalibrated. The facility for 3D dosimetry was essential to gain a comprehensive understanding of the targeting error in 3D.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
J Phys Conf Ser
DOI
ISSN
1742-6588
Publication Date
2013
Volume
444
Start / End Page
12070
Location
England
Related Subject Headings
- 51 Physical sciences
Citation
APA
Chicago
ICMJE
MLA
NLM
Oldham, M., Newton, J., Rankine, L., Adamovics, J., Kirsch, D., & Das, S. (2013). How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator? In J Phys Conf Ser (Vol. 444, p. 12070). England. https://doi.org/10.1088/1742-6596/444/1/012070
Oldham, M., J. Newton, L. Rankine, J. Adamovics, D. Kirsch, and S. Das. “How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator?” In J Phys Conf Ser, 444:12070, 2013. https://doi.org/10.1088/1742-6596/444/1/012070.
Oldham M, Newton J, Rankine L, Adamovics J, Kirsch D, Das S. How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator? In: J Phys Conf Ser. 2013. p. 12070.
Oldham, M., et al. “How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator?” J Phys Conf Ser, vol. 444, 2013, p. 12070. Pubmed, doi:10.1088/1742-6596/444/1/012070.
Oldham M, Newton J, Rankine L, Adamovics J, Kirsch D, Das S. How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator? J Phys Conf Ser. 2013. p. 12070.
Published In
J Phys Conf Ser
DOI
ISSN
1742-6588
Publication Date
2013
Volume
444
Start / End Page
12070
Location
England
Related Subject Headings
- 51 Physical sciences