A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance.

Publication ,  Journal Article
Wang, J; Chen, W; Studenski, M; Cui, Y; Lee, AJ; Xiao, Y
Published in: Phys Med Biol
July 7, 2013

The goal of this work is to develop a plan-quality evaluation program for clinical routine and multi-institutional clinical trials so that the overall evaluation efficiency is improved. In multi-institutional clinical trials evaluating the plan quality is a time-consuming and labor-intensive process. In this note, we present a semi-automated plan-quality evaluation program which combines MIMVista, Java/MATLAB, and extensible markup language (XML). More specifically, MIMVista is used for data visualization; Java and its powerful function library are implemented for calculating dosimetry parameters; and to improve the clarity of the index definitions, XML is applied. The accuracy and the efficiency of the program were evaluated by comparing the results of the program with the manually recorded results in two RTOG trials. A slight difference of about 0.2% in volume or 0.6 Gy in dose between the semi-automated program and manual recording was observed. According to the criteria of indices, there are minimal differences between the two methods. The evaluation time is reduced from 10-20 min to 2 min by applying the semi-automated plan-quality evaluation program.

Duke Scholars

Published In

Phys Med Biol

DOI

EISSN

1361-6560

Publication Date

July 7, 2013

Volume

58

Issue

13

Start / End Page

N181 / N187

Location

England

Related Subject Headings

  • Software
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiotherapy, Conformal
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Quality Assurance, Health Care
  • Nuclear Medicine & Medical Imaging
  • Clinical Trials as Topic
  • China
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wang, J., Chen, W., Studenski, M., Cui, Y., Lee, A. J., & Xiao, Y. (2013). A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance. Phys Med Biol, 58(13), N181–N187. https://doi.org/10.1088/0031-9155/58/13/N181
Wang, Jiazhou, Wenzhou Chen, Matthew Studenski, Yunfeng Cui, Andrew J. Lee, and Ying Xiao. “A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance.Phys Med Biol 58, no. 13 (July 7, 2013): N181–87. https://doi.org/10.1088/0031-9155/58/13/N181.
Wang J, Chen W, Studenski M, Cui Y, Lee AJ, Xiao Y. A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance. Phys Med Biol. 2013 Jul 7;58(13):N181–7.
Wang, Jiazhou, et al. “A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance.Phys Med Biol, vol. 58, no. 13, July 2013, pp. N181–87. Pubmed, doi:10.1088/0031-9155/58/13/N181.
Wang J, Chen W, Studenski M, Cui Y, Lee AJ, Xiao Y. A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance. Phys Med Biol. 2013 Jul 7;58(13):N181–N187.
Journal cover image

Published In

Phys Med Biol

DOI

EISSN

1361-6560

Publication Date

July 7, 2013

Volume

58

Issue

13

Start / End Page

N181 / N187

Location

England

Related Subject Headings

  • Software
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiotherapy, Conformal
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Quality Assurance, Health Care
  • Nuclear Medicine & Medical Imaging
  • Clinical Trials as Topic
  • China