Skip to main content
Journal cover image

Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing.

Publication ,  Journal Article
Estrada, R; Tomasi, C; Cabrera, MT; Wallace, DK; Freedman, SF; Farsiu, S
Published in: Biomed Opt Express
October 1, 2011

Indirect ophthalmoscopy (IO) is the standard of care for evaluation of the neonatal retina. When recorded on video from a head-mounted camera, IO images have low quality and narrow Field of View (FOV). We present an image fusion methodology for converting a video IO recording into a single, high quality, wide-FOV mosaic that seamlessly blends the best frames in the video. To this end, we have developed fast and robust algorithms for automatic evaluation of video quality, artifact detection and removal, vessel mapping, registration, and multi-frame image fusion. Our experiments show the effectiveness of the proposed methods.

Duke Scholars

Published In

Biomed Opt Express

DOI

EISSN

2156-7085

Publication Date

October 1, 2011

Volume

2

Issue

10

Start / End Page

2871 / 2887

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4003 Biomedical engineering
  • 3212 Ophthalmology and optometry
  • 0912 Materials Engineering
  • 0205 Optical Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Estrada, R., Tomasi, C., Cabrera, M. T., Wallace, D. K., Freedman, S. F., & Farsiu, S. (2011). Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing. Biomed Opt Express, 2(10), 2871–2887. https://doi.org/10.1364/BOE.2.002871
Estrada, Rolando, Carlo Tomasi, Michelle T. Cabrera, David K. Wallace, Sharon F. Freedman, and Sina Farsiu. “Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing.Biomed Opt Express 2, no. 10 (October 1, 2011): 2871–87. https://doi.org/10.1364/BOE.2.002871.
Estrada R, Tomasi C, Cabrera MT, Wallace DK, Freedman SF, Farsiu S. Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing. Biomed Opt Express. 2011 Oct 1;2(10):2871–87.
Estrada, Rolando, et al. “Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing.Biomed Opt Express, vol. 2, no. 10, Oct. 2011, pp. 2871–87. Pubmed, doi:10.1364/BOE.2.002871.
Estrada R, Tomasi C, Cabrera MT, Wallace DK, Freedman SF, Farsiu S. Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing. Biomed Opt Express. 2011 Oct 1;2(10):2871–2887.
Journal cover image

Published In

Biomed Opt Express

DOI

EISSN

2156-7085

Publication Date

October 1, 2011

Volume

2

Issue

10

Start / End Page

2871 / 2887

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4003 Biomedical engineering
  • 3212 Ophthalmology and optometry
  • 0912 Materials Engineering
  • 0205 Optical Physics