
Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing.
Publication
, Journal Article
Estrada, R; Tomasi, C; Cabrera, MT; Wallace, DK; Freedman, SF; Farsiu, S
Published in: Biomed Opt Express
October 1, 2011
Indirect ophthalmoscopy (IO) is the standard of care for evaluation of the neonatal retina. When recorded on video from a head-mounted camera, IO images have low quality and narrow Field of View (FOV). We present an image fusion methodology for converting a video IO recording into a single, high quality, wide-FOV mosaic that seamlessly blends the best frames in the video. To this end, we have developed fast and robust algorithms for automatic evaluation of video quality, artifact detection and removal, vessel mapping, registration, and multi-frame image fusion. Our experiments show the effectiveness of the proposed methods.
Duke Scholars
Published In
Biomed Opt Express
DOI
EISSN
2156-7085
Publication Date
October 1, 2011
Volume
2
Issue
10
Start / End Page
2871 / 2887
Location
United States
Related Subject Headings
- 5102 Atomic, molecular and optical physics
- 4003 Biomedical engineering
- 3212 Ophthalmology and optometry
- 0912 Materials Engineering
- 0205 Optical Physics
Citation
APA
Chicago
ICMJE
MLA
NLM
Estrada, R., Tomasi, C., Cabrera, M. T., Wallace, D. K., Freedman, S. F., & Farsiu, S. (2011). Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing. Biomed Opt Express, 2(10), 2871–2887. https://doi.org/10.1364/BOE.2.002871
Estrada, Rolando, Carlo Tomasi, Michelle T. Cabrera, David K. Wallace, Sharon F. Freedman, and Sina Farsiu. “Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing.” Biomed Opt Express 2, no. 10 (October 1, 2011): 2871–87. https://doi.org/10.1364/BOE.2.002871.
Estrada R, Tomasi C, Cabrera MT, Wallace DK, Freedman SF, Farsiu S. Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing. Biomed Opt Express. 2011 Oct 1;2(10):2871–87.
Estrada, Rolando, et al. “Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing.” Biomed Opt Express, vol. 2, no. 10, Oct. 2011, pp. 2871–87. Pubmed, doi:10.1364/BOE.2.002871.
Estrada R, Tomasi C, Cabrera MT, Wallace DK, Freedman SF, Farsiu S. Enhanced video indirect ophthalmoscopy (VIO) via robust mosaicing. Biomed Opt Express. 2011 Oct 1;2(10):2871–2887.

Published In
Biomed Opt Express
DOI
EISSN
2156-7085
Publication Date
October 1, 2011
Volume
2
Issue
10
Start / End Page
2871 / 2887
Location
United States
Related Subject Headings
- 5102 Atomic, molecular and optical physics
- 4003 Biomedical engineering
- 3212 Ophthalmology and optometry
- 0912 Materials Engineering
- 0205 Optical Physics